AV-14F3/AV-1435

 

 

 

 

 

 

 

 

AV-1435EE/AV-1435TEE

 

 

 

 

 

 

 

 

AV-14FMT3/AV-1438

 

 

 

 

 

 

 

 

AV-14FMG3/AV- 14FMG3B

 

 

 

 

 

 

 

 

 

 

Item

Measuring

 

Test point

 

Ad justment part

Description

instrument

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ad justment

Signal

 

 

DELAY POINT

1.Input a black and white signal (colour off).

of DELAY

generator

 

 

(AGC TAKE-OVER)

2.Enter the SERVICE MENU.

 

 

 

POINT

Remote

 

 

 

 

 

3.Select 1. IF from the SERVICE MENU.

(AGC)

control unit

 

 

 

 

 

4.Select 2. DELAY POINT by pressing the 2 key on the remote

 

 

 

 

 

 

 

 

control unit.

 

 

 

 

 

 

 

 

5.Set the setting values of the setting items as shown bellow table.

 

 

 

 

 

 

 

 

6.Then adjust the MENU - or + key until video noise disappears.

 

 

 

 

 

 

 

 

7.Turn to other channels and make sure that there are no

 

 

 

 

 

 

 

 

irregularities.

 

 

DELAY POINT

UHF

 

 

 

 

 

 

 

AGC TAKE-OVER **

 

 

 

 

 

 

 

- / + : OPERATE

DISP : EXIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting Item

Variable range

Initial setting value

 

 

 

 

 

 

 

MATSUSHITA

DELAY POINT

NT SC 3.58

 

(QAU0287-001)

 

0127

45

(AGC TAKE OVER)

 

OTHER

 

 

 

 

35

 

 

 

 

 

 

 

No. 52026

21

Page 21
Image 21
JVC AV-1435TEE, AV-14FMT3, AV-14FMG3B, AV-1435EE, AV-1438, AV-14FMG3/-A Delay Point, Agc, Matsushita, AGC Take Over Other