AV-14F3/AV-1435

 

 

 

 

AV-1435EE/AV-1435TEE

 

 

 

 

AV-14FMT3/AV-1438

 

 

 

 

AV-14FMG3/AV- 14FMG3B

 

 

 

 

Item

 

Measuring

Test point

Ad justment part

Description

instrument

 

 

 

 

 

Ad justment

Signal

TP-47G/R

5.

COLOUR

[Method of adjustment using measuring instrument]

of SUB

generator

 

 

 

 

 

 

 

 

 

 

COLOUR

Oscillo-

TP-E (#)

PAL COLOUR

1.Input a PAL full field colour bar signal (75% white).

 

[CRT SOCKET

 

scope

 

 

2.Enter the SERVICE MENU.

 

 

 

PWB]

 

 

 

Remote

 

 

 

3.Select 2. V/C from SERVICE MENU.

 

control unit

 

 

 

4.Select 5. COLOUR with the MENU /key.

 

 

 

 

 

 

5.Set the initial setting value of PAL COLOUR with the MENU

 

 

 

 

 

 

- / + key.

 

 

 

 

 

 

6.Connect the oscilloscope between TP-47G/R and TP-E ( #).

 

 

 

 

B

 

7.Adjust PAL COLOUR to bring the value of (A) in the illustration

 

 

 

R

 

 

to +12V(W-G). (Voltage value between (W) and (G))

 

 

 

Mg

 

 

 

 

 

 

 

 

 

 

 

 

()

 

 

 

W

 

 

0V

 

 

 

Y

(A)

()

 

 

 

 

Cy

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

SECAM COLOUR

1.Input a SECAM full field colour bar signal (75% white).

 

2.Set the initial setting value of SECAM COLOUR with the MENU

 

- / + key.

 

3.Adjust SECAM COLOUR to bring the value of (A) in the

 

illustration to +10V(W-G). (Voltage value between (W) and (G))

NTSC 3.58 COLOUR 1.Input a NTSC 3.58 full field colour bar signal (75% white).

2.Set the initial setting value of NTSC 3.58 COLOUR with the MENU - / + key.

3.Adjust NTSC 3.58 COLOUR to bring the value of (A) in the illustration to +10V(W-G). (Voltage value between (W) and (G))

NTSC 4.43 COLOUR

When NTSC 3.58 is set, NTSC 4.43 will be automatically set at the respective values .

24

No. 52026

Page 24
Image 24