Item Measuring
instrument Test point Adjustment part Description
5. COLOUR [Method of adjustment using measuring instrument]
PAL COLOUR 1. Input a PAL f ull field colou r bar sig nal (75% w hite) .
2. Enter the SERVICE MENU.
3. Select 2. V/C from SERVICE MENU.
4. Select 5. COLOUR with the MENU / key.
5. Set the initial setting value of PAL COLOUR with the MENU
- / + key.
6. Connect the osc ill osc ope be twee n TP-4 7G/ R and T P-E ( #
).
7. Adjust PAL COLOUR to bring th e value of (A) in the illustration
to +12V (W- G). ( Volt age val ue b etwe en (W) an d (G))
SECAM COLOUR 1. Input a SECAM full field colour bar signal (75% white).
2. Set the initial settin
g
value of SECAM COLOUR with the MENU
- / + key.
3. Adjust SE CAM COLOUR to bring the v alue of (A) in the
illust ration t o +10V
(
W-G
)
.
(
Volta
g
e value between
(
W
)
and
(
G
))
NTSC 3.58 COLOUR 1. Input a NTSC 3.58 full fie ld colo ur b ar si gnal (75 % white) .
2. Set the initial setting value of NTSC 3.58 COLOUR with the
MENU - / + key.
3. Adjust N TSC 3.58 COL OUR to bring the value of (A) in the
illust ration t o +10V
(
W-G
)
.
(
Volta
g
e value between
(
W
)
and
(
G
))
Adju s t men t
of SUB
COLOUR
Signal
generator
Oscillo-
scope
Remote
control unit
TP-47G/R
TP-E (#
##
#)
[CRT SOCKET
PWB]
NTSC 4.43 COLOUR When N TSC 3.5 8 is s et, N TSC 4. 43 wi ll be autom atica lly s et at t he
respec tive values .
W
Y
Cy
G
M
g
R
B
(A)
0V
()
()