AV-14F3/AV-1435 AV-1435EE/AV-1435TEE AV-14FMT3/AV-1438 AV-14FMG3/AV- 14FMG3B

Item

Measuring instrument

Test point

Ad justment part

Description

Ad justment

Remote

 

7.SECAM

of SECAM

control unit

 

BL ADJUST

 

 

BL ACK

Signal

 

 

 

 

 

 

OFFSET

generator

 

 

 

 

 

 

 

KEY ASSIGNMENT OF REMOTE CONTROL UNIT

COLOUR

 

 

ON

 

 

1

2

3

COLOUR

 

 

OFF

 

 

4

5

6

7

8

9

[Method of adjustment using measuring instrument]

1.Input a SECAM full field colour bar signal.

2.Enter the SERVICE MENU.

3.Select 2. V/C from SERVICE MENU.

4.Select 7. SECAM BL ADJUST with MENU /key.

5.Set the initial setting value with the MENU - / + key.

6.Switch the key (colour OFF) and key (colour ON) on the remote control and make sure that there is no colour on the black and white screen.

7.If the black and white screen is not best with the initial setting value, make fine adjustment until you get the best black and white screen.

8.While watching the screen, adjust the value to be the same colour between ON & OFF by ten key on the remote control unit.

9.Press the DISPLAY key twice to return to the normal screen.