No. 52026
A
V-14F3/AV-1435
A
V-1435EE/AV-1435TEE
A
V-14FMT3/AV-1438
A
V-14FMG3/AV-14FMG3B
26
Item Measuring
instrument Test
p
oint Adjustment part Description
7.SECAM
BL ADJUST
[Method of adjustment using measuring instrument]Adju s t men t
of SECAM
BLAC K
OFFSET
Remote
control unit
Signal
generator
1. Input a SEC AM ful l fiel d col our b ar si gnal.
2. Enter the SERVICE MENU.
3. Select 2. V/C from SERVIC E MENU.
4. Select 7. SECAM BL ADJUST with MENU / key.
5. Set the initial setting value with the MENU - / + key.
6. Switch the key (col our OFF) and key (colou r ON) on t he
remote control and ma ke sure that th ere is no colour on the
black and wh ite s cree n.
7. If the bl ack an d white s creen i s not bes t with the init ial sett ing
value, make fine adjustment until you g et the best black and
white scr een.
8. While wat ching the sc reen, adj ust the val ue to be th e same
colour betwee n ON & OFF by ten key on t he rem ote contr ol
unit.
9. Press the DISPL AY key t wice to r eturn to the normal screen.
KEY ASSIGNMENT OF REMOTE CONTROL UNIT
123
456
789
COLOUR
ON
COLOUR
OFF