Warning Status
The latest error code (Warning Status) appears in the Main Menu when an abnormality occurs in the projector. Error details are as follows:
Error Code | Meaning |
|
|
1 | Lamp 1 does not turn on. |
|
|
2 | Accumulated lamp time for Lamp 1 has exceeded 2000 hours. |
|
|
6 | Lamp 1 goes off during projection. |
|
|
8 | Abnormally high temperature in the projector. |
|
|
9 | Abnormally high temperature around the intake vent. |
|
|
A | Abnormally high ambient temperature around the lamp. |
|
|
15 | The lamp cover is open. |
|
|
30 | Trouble with CPU circuit board. |
|
|
31 | Trouble with MAIN circuit board. |
|
|
32 | Trouble with |
|
|
33 | Trouble with |
|
|
40 | FAN1 (the cooling fan for Lamp 1) has stopped. |
|
|
41 | FAN2 (the cooling fan for Lamp 2) has stopped. |
|
|
42 | FAN3 (the cooling fan for overall exhaust/prism) has stopped. |
|
|
43 | FAN4 (the auxiliary cooling fan for exhaust) has stopped. |
|
|
44 | FAN5 (the cooling fan for the lighting system (PCS)) has stopped. |
|
|
45 | FAN6 (the cooling fan for the device) has stopped. |
|
|
46 | FAN7 (the cooling fan for the MAIN circuit board) has stopped. |
|
|
47 | FAN8 (the cooling fan for the DD circuit board) has stopped. |
|
|
48 | FAN9 (the cooling fan for the power supply of the circuit) has stopped. |
|
|
49 | FAN10 (the cooling fan for the power supply of Lamp 1) has stopped. |
|
|
4A | FAN11 (the cooling fan for the power supply of Lamp 2) has stopped. |
|
|
50 | Trouble with mechanical shutter. |
|
|
51 | Lamp 2 does not turn on. |
|
|
52 | Accumulated lamp time for Lamp 2 has exceeded 2000 hours. |
|
|
56 | Lamp 2 goes off during projection. |
|
|
55