TROUBLESHOOTING (cont.)

SYMPTOM

 

POSSIBLE CAUSES

 

CORRECTIVE ACTION

45. The LCD monitor, the

 

45.

 

45. • Wipe them gently with soft

viewfinder and the lens have

 

————

 

cloth. Wiping strongly can

become dirty

 

 

cause damage ( pg. 78).

 

 

 

(ex. fingerprints).

 

 

 

 

 

 

 

 

 

46. An unusual mark appears.

 

46.

 

46. • Check the section of the

 

 

————

 

manual that explains LCD

 

 

 

monitor/viewfinder indica-

 

 

 

 

 

 

 

 

tions ( pg. 88 – 92).

 

 

 

 

 

47. An error indication

 

47. • A malfunction of some kind

 

47. • Remove the power supply

(E01 — E06) appears.

 

has occurred. In this case the

 

(battery pack, etc.) and wait a

 

 

camcorder’s functions

 

few minutes for the indication

 

 

become unusable.

 

to clear. When it does, you

 

 

 

 

can resume using the

 

 

 

 

camcorder.

 

 

 

 

If the indication remains even

 

 

 

 

though you repeat the above

 

 

 

 

two or three times, please

 

 

 

 

consult your nearest JVC

 

 

 

 

dealer.

 

 

 

 

 

48. The charger indicator on the

 

48. • The temperature of the battery

 

48. • To protect the battery, it is

AC Power Adapter/Charger

 

is extremely high/low.

 

recommended to charge it in

does not light.

 

• Charging is difficult in places

 

places with a temperature of

 

 

subject to extremely high/low

 

10°C to 35°C ( pg. 93).

 

 

temperatures.

 

 

 

 

 

 

 

49. Picture does not appear on

 

49. • The viewfinder is pulled out.

 

49. • Push the viewfinder back in.

the LCD monitor.

 

• The LCD monitor's brightness

 

• Adjust the brightness of the

 

 

setting is too dark.

 

LCD monitor ( pg. 16).

 

 

 

 

• If the monitor is tilted upward

 

 

 

 

180 degrees, open the

 

 

 

 

monitor fully ( pg. 16).

 

 

 

 

 

50. When the image is printed

 

50. • This is not a malfunction.

 

50. • By recording with “DIS”

from the printer, a black bar

 

 

 

activated ( pg. 28) this can

appears at the bottom of the

 

 

 

be avoided.

screen.

 

 

 

 

 

 

 

 

 

51. When the camcorder is

 

51. • The DV cable was plugged/

 

51. • Turn the camcorder’s power

connected via the DV

 

unplugged with power turned

 

off and on again, then operate

connector, the camcorder

 

on.

 

it.

does not operate.

 

 

 

 

 

 

 

 

 

52. During transport, the lens

 

52.

 

52. • Do not subject the camcorder

cover opens.

 

 

 

to shock or excessive

 

 

————

 

vibration during transport.

 

 

 

 

• Turn the camcorder on and

 

 

 

 

off. The lens cover closes.

 

 

 

 

 

53. The MultiMediaCard cannot

 

53.

 

53. • Push in the MultiMediaCard a

be removed from the

 

————

 

few more times ( pg. 12).

camcorder.

 

 

 

 

 

 

 

 

 