JVC KD-SH99R service manual ERROR CODE of Panel mechanism, 1-17

Models: KD-SH99R

1 41
Download 41 pages 46.82 Kb
Page 3
Image 3

KD-SH99R

<ERROR CODE of Panel mechanism>

Memory to EEPROM of 6 digits, 1st and 2nd digit are indicate the operation mode when occur the error, 3rd to 6th digit are indicate details of error.

LCD indication time is use lower 2digits of details of error. This series is indicate ERR XX (XX is error code).

<ex.> When details of error is 0A0001 , it is indicate ERR 01, details of error is 0E0031 , it is ERR 31. Switch is from this side sequentially PSW1, PSW2,.....PSW6.

 

 

Details of error

Error code

 

 

 

1. Error of door open (fault of PSW1)

 

 

(1) Time out by PSW1 not changed

0A0001

 

 

 

 

 

(2)

PSW1 change during waiting 300ms after open position detected

0A0002

 

 

 

2. Error of door close (fault of PSW6)

 

 

 

 

 

(1) Time out by PSW6 not changed

0B0006

 

 

 

 

 

(2)

PSW6 change during waiting 300ms after close position detected

0B0007

 

 

 

3. Error of shift to DETACH position (fault of PSW5)

 

 

 

 

 

(1) Time out by PSW5 not changed to open side

0C0011

 

 

 

 

 

(2)

Shift to open side, pass the DETACH position then detect ANGLE1

0C0012

 

 

 

 

(3) Time out by PSW5 not changed to close side

0C0013

 

 

 

 

 

(4)

Shift to close side, pass the DETACH position then detect close position

0C0014

 

 

 

4. Error of angle adjustment

 

 

4-1 Shift to ANGLE1 (fault of PSW4)

 

 

 

 

 

(1) Time out by PSW4 not changed to shift for open side

0D0021

 

 

 

 

 

(2)

Shift to open side, pass the ANGLE1 then detect ANGLE2

0D0022

 

 

 

 

(3) Time out by PSW4 not changed to shift for close side

0D0023

 

 

 

 

 

(4)

Shift to close side, pass the ANGLE1 then detect DETACH position

0D0024

 

 

 

 

4-2 Shift to ANGLE2 (fault PSW3)

 

 

 

 

 

(1) Time out by PSW3 not change to shift for open side

0E0031

 

 

 

 

 

(2)

Shift to open side, pass the ANGLE2 then detect ANGLE3

0E0032

 

 

 

 

(3) Time out by PSW3 not changed to shift for close side

0E0033

 

 

 

 

 

(4)

Shift to close side, pass the ANGLE2 then detect ANGLE1

0E0034

 

 

 

 

4-3 Shift to ANGLE3 (fault PSW2)

 

 

 

 

 

(1) Time out by PSW2 not changed to shift for open side

0F0041

 

 

 

 

 

(2)

Shift to open side, pass the ANGLE3 then detect OPEN position

0F0042

 

 

 

 

(3) Time out by PSW2 not changed for shift for close side

0F0043

 

 

 

 

 

(4)

Shift to close side, pass the ANGLE3 then detect ANGLE2

0F0044

 

 

 

5. PSW fault condition at initialize

000000

 

When all PSW is checked immediately after RESET, and the state of SWITCH which

 

 

cannot be originally is detected, it is displayed as ERR 00.

 

 

 

 

 

1-17

Page 3
Image 3
JVC KD-SH99R service manual ERROR CODE of Panel mechanism, 1-17