5. Menu screen settings (continued)

SYSTEM SETTING screen

MENU (QUICK) screen

[ ] indicates the factory setting

 

 

 

Item

Set Value

 

 

Contents

AE DISPLAY

[OFF]

Used to set whether the ALC, EEI and IRIS values are

 

ON

displayed on the analog output screen.

 

 

OFF:

No on-screen-display

 

 

ON:

On-screen-display

FRZ DISPLAY

[ON]

Used to set whether the “FREEZE” indicator is shown on

 

OFF

the screen at the time of trigger input.

 

 

ON:

Displayed

 

 

OFF:

Not displayed

FRZ CANCEL

[MANUAL]

Sets the method for canceling the FREEZE when the

 

AUTO (1s)

monitor screen is in FREEZE condition when connection

 

AUTO (3s)

is made through digital output.

 

AUTO (5s)

MANUAL

:

Cancelled by trigger input.

 

OFF

AUTO(1s)

:

Cancelled after 1 second.

 

 

AUTO(3s)

:

Cancelled after 3 seconds.

 

 

AUTO(5s)

:

Cancelled after 5 seconds.

 

 

OFF

:

Not cancelled.

*When set to “AUTO” or “OFF”, the displayed screen can be updated by trigger input during the FREEZE condi- tion.

TEST PATTERN

[BAR]

Sets the test pattern type output when the function set-

 

RAMP

ting switch No.1 <TEST PATTERN> is set to “ON”.

 

IMPULSE

BAR

:

“BAR” pattern is output.

 

 

RAMP

:

“RAMP” pattern is output.

 

 

IMPULSE :

“IMPULSE” pattern is output.

LEVEL

[0.7V]

Sets the level of the color signal bar output from the KY-

When “BAR”/

0.57V

1030’s [ANALOG OUT] connector.

“IMPULSE”

 

0.7V:

0.7V test signal is output

is selected

 

0.57V:

0.57V test signal is output

MENU RESET

 

Resets all the set values of menus to the initial values.

 

 

 page E43, Resetting menu settings

[ ] indicates the factory setting

Item

Set Value

AE LEVEL

–128

 

–127

 

 

[0]

 

 

 

126

 

127

IRIS LEVEL

0

 

1

 

 

 

[255]

SHUTTER

[STEP]

 

V.SCAN

 

RANDOM

 

EEI

 

OFF

SPEED

4s

When

2s

“STEP” is

1s

selected

1/2s

 

1/4s

 

[1/8s]

 

1/15s

 

1/30s

 

1/60s

 

1/125s

 

1/250s

 

1/500s

 

1/1000s

 

1/2000s

 

 

Contents

Used to adjust the video level when using auto iris, ALC

and EEI.

 

 

Increase the number :

raise the level

Decrease the number :

lower the level

MEMO

 

 

”----“ is displayed when auto iris, ALC, and EEI are all set to

not work.

 

 

Used to set the iris level when the IRIS MODE is set to

“MANUAL”.

 

 

Increase the number :

open iris

Decrease the number :

close iris

Used to switch the shutter mode.

STEP:

The shutter speed can be changed with the

V. SCAN:

[SPEED] item.

The shutter speed can be changed with the

 

[SPEED] item.

 

Enables more detailed setting than [STEP].

RANDOM: Used to synchronize the CCD accumulation

 

timing with the trigger input.

 

The shutter speed can be changed with the

EEI:

[SPEED] item.

Used to automatically change the shutter

 

speed in accordance with the brightness of the

OFF:

subject.

 

Fixed at 1/7.5 s.

The shutter speed can be changed when SHUTTER is

set to “STEP”, “V.SCAN” or “RANDOM”.

E40

E41

Page 23
Image 23
JVC KY-F1030 manual System Setting screen, Menu Quick screen