5. Menu screen settings (continued)

EXPOSURE screen (continued) [ ] indicates the factory setting

EXPOSURE screen (continued)

[ ] indicates the factory setting

Item

SHUTTER

SPEED When “STEP” is selected

SPEED When “V.SCAN” is selected

SPEED When “RANDON” is selected

Set Value

[STEP] V.SCAN RANDOM EEI OFF

4s 2s 1s 1/2s 1/4s [1/8s] 1/15s 1/30s 1/60s 1/125s 1/250s 1/500s 1/1000s 1/2000s

3.990s • [1/7.501s] • • 1/5906.836s

1/7.500s • [1/126.134s] • • 1/5648.193s

 

Contents

Used to switch the shutter mode.

STEP:

The shutter speed can be changed with the

V. SCAN:

[SPEED] item.

The shutter speed can be changed with the

 

[SPEED] item.

 

Enables more detailed setting than [STEP].

RANDOM: Used to synchronize the CCD accumulation

 

timing with the Trigger input.

 

The shutter speed can be changed with the

EEI:

[SPEED] item.

Used to automatically change the shutter

 

speed in accordance with the brightness of the

 

subject.

OFF:

Fixed at 1/7.5 s.

The shutter speed can be changed when SHUTTER is

set to “STEP”, “V.SCAN” or “RANDOM”.

MEMO

 

When the shutter speed is slower than 1/7.5 s, the following phenomena may occur.

1)The screen update rate becomes longer in the case of digital output.

2)The displayed image will appear intermittently in the case of analog output.

3)Time will be required for the auto white, auto iris and ALC operations.

 

If the shutter speed is set slower than 1 s, these

 

operations will behave as follows.

 

Auto white

:

Auto white balance function cannot be started.

 

Auto iris

:

(  page E23 White balance adjustment)

 

Stops at the iris value at that time.

 

ALC

:

Stops at the sensitivity at that time.

 

To use a shutter speed slower than 1 s, use with the fol-

 

lowing settings selected:

 

IRIS MODE

:

MANUAL

GAIN

:

STEP or V.GAIN

There may be shortage of light when the shutter speed is

 

increased. In this case, adjust the iris or sensitivity. Atten-

 

tion should be paid to the picture quality when the sensi-

 

tivity is raised since the image becomes coarse.

Item

Set Value

GAIN

[STEP]

 

ALC

 

V.GAIN

LEVEL When

[0dB]

“STEP” is

+6dB

selected

+12dB

LEVEL When

[0dB]

“V. GAIN” is

+0.2dB

selected

+0.4dB

 

 

 

+12dB

ALC MAX

[+12dB]

 

+6dB

EEI LIMIT

[1/7.5s]

 

1s

 

Contents

Used to switch the sensitivity mode.

STEP:

The sensitivity can be changed with the “LEVEL”

 

item.

ALC:

The sensitivity is automatically changed in ac-

 

cordance with ambient brightness.

V.GAIN:

The sensitivity can be changed in detail with

 

the “LEVEL” item.

Sets the maximum sensitivity of ALC, which automatically

switches the sensitivity in accordance with ambient bright-

ness.

 

Sets the minimum value for the shutter speed when the

shutter mode is set to “EEI”.

1/7.5s:

Set to 1/7.5s.

1s:

Set to 1s.

*When analog output is used, the monitor image will be stopping many times when the shutter speed becomes slower, so set at “1/75.s”.