4 Remove the inner dome

The inner dome is fastened using 2 catches. Remove the inner dome by unfastening it from the catches.

5 Remove the outer casing

(This mounting method does not make use of an outer casing. )

ARemove the fastening screw from the camera unit using a screwdriver

BTurn the camera unit in the anti-clockwise direction to remove the outer casing

6 Remove the attached fall prevention wire

Remove the fall prevention wire that is attached to the camera unit.

Inner dome

4 5 A

Camera unit fastening screw

6 5 B

Outer casing

Connection

Memo:

For details, please also refer to the [READ ME FIRST] (sheet) provided.

Note:

For your safety, turn on the power only after all connections are completed.

1Mount the fall prevention wire that connects the camera and the ceiling to the camera unit

2Connect the alarm cables and audio cables

3Connect the LAN cable

4Connect the power cable

Note:

Connection of a power cable is not necessary when PoE is used.

Memo:

For cables that are not used, be sure to wrap the ends individually with insulating tape.

5 Insert the camera unit into the hole in the ceiling

5

2, 4

Solder welding or crimping

Fall prevention

wire

Insulating tape

1 3

11