Connecting the Alarm Input/Output Cable

Alarm Input

Connect the cable to sensors such as infrared sensors, door sensors, metal sensors and manual switches.

Input Requirements

Non-voltage relay NPN open collector input

Polarity of input detection can be selected

using a software

Make/break (500 ms and above)

Circuit current of 1 mA during low-level input

Applied voltage of 3.3 V during high-level

Alarm output

Connect to alarm devices such as alarm, indicator, light or buzzer.

Output Requirements

NPN open collector output equivalent (Refer to the INSTRUCTIONS (Setting) on procedures to set the output logic. )

Allowable applied voltage: DC 12 V and below

Allowable inflow current: 50 mA

Momentary (100 ms to 5000 ms) output (Refer to [INSTRUCTIONS (Setting)] for procedures to set the time. )

Alarm device

input

This unit

(example)

This unit

 

 

Sensor example

 

 

(1)

DC3.3 V Input 1 or

VCC

R

Input 2

 

 

 

OUT

R

 

 

 

3.3 V

1 mA

 

 

GND

GND

 

(Alarm input equivalent

 

Sensor example

circuit)

 

 

(2)

 

 

 

Relay switch, etc.

OUT

GND

Output 1 or

 

 

 

 

 

DC 12 V

IN R

 

 

 

 

Output 2

 

 

 

 

 

 

 

GND GND

(Alarm output equivalent circuit)

Note:

Connect the GND cable of the camera to the GND terminal of the alarm device.

13