Connecting the Alarm Input/Output Cable
Alarm Input
Connect the cable to sensors such as infrared sensors, door sensors, metal sensors and manual switches.
Input Requirements
● |
● Polarity of input detection can be selected |
using a software |
● Make/break (500 ms and above) |
● Circuit current of 1 mA during |
● Applied voltage of 3.3 V during |
Alarm output
Connect to alarm devices such as alarm, indicator, light or buzzer.
Output Requirements
●NPN open collector output equivalent (Refer to the INSTRUCTIONS (Setting) on procedures to set the output logic. )
●Allowable applied voltage: DC 12 V and below
●Allowable inflow current: 50 mA
●Momentary (100 ms to 5000 ms) output (Refer to [INSTRUCTIONS (Setting)] for procedures to set the time. )
Alarm device
input |
This unit
(example)
This unit |
|
| Sensor example | |
|
| (1) | ||
DC3.3 V Input 1 or | ||||
VCC | ||||
R | Input 2 |
|
| |
| OUT | R | ||
|
| |||
| 3.3 V | 1 mA |
| |
| GND | GND |
| |
(Alarm input equivalent |
| Sensor example | ||
circuit) |
|
| (2) | |
|
|
| Relay switch, etc. |
OUT
GND
Output 1 or |
|
|
|
|
| DC 12 V |
IN R |
|
|
|
| ||
Output 2 |
|
|
| |||
|
|
|
|
GND GND
(Alarm output equivalent circuit)
Note:
●Connect the GND cable of the camera to the GND terminal of the alarm device.
13