OTHERS

Troubleshooting

Symptom

 

Remedy

 

 

The operation becomes un-

Drop in voltage of the power supply can

stable

be considered. Check the length and

 

thickness of the power supply cable.

 

( Page 17)

 

 

 

 

 

 

The auto iris will not operate

Set the VIDEO/DC switch on the side

 

of unit according to the type of auto iris

 

lens used.

 

 

 

( Pages 20, 21)

 

 

 

 

 

 

There is noise in the screen

Lower the gain using the AGC MODE

or increase in residual im-

menu item.

 

 

ages

ULTRA SUPER HIGH MID

LOW OFF

 

(MAX)

 

 

(MIN)

 

Gain

 

 

 

 

 

 

( Page 31)

 

 

The colors of the screen are

When using in an environment where

not natural

there are changes in the light source,

 

set the WHITE BALANCE menu item

 

to ATW.

 

 

 

( Page 33)

 

 

 

 

 

 

White balance adjusted

Set the WHITE BALANCE menu item

automatically/manually

to AWB or MANUAL.

 

 

cannot be used

( Page 33)

 

 

The camera title will not ap-

Set the CAMERA TITLE menu item to

pear

ON.

 

 

 

( Page 36)

 

 

The vertical phase cannot be

When adjusting the vertical phase dur-

adjusted using the V PHASE

ing line lock, set the LL/INT switch on

menu item

the back of unit to LL.

 

 

 

( Page 11)

 

 

 

 

 

 

 

40

Page 46
Image 46
JVC TK-WD31 manual Troubleshooting, Symptom Remedy, Operation becomes un, Ultra Super High MID LOW OFF MAX MIN