Step Two: Remove hoses

Step Two: Remove hoses

After the screws have been removed, take the ½ inch open-ended wrench, and loosen the nut that connects the hose to the valve by turning it counter-clockwise, and remove the hose.

Unscrew nut counter-clockwise

Next, cut the hose to the plastic elbow 3/8 inch from the end of the plastic elbow using the wire cutter.

cut tubing

Repeat steps one and two to dismount the second valve before proceeding to step three.

Step Three: Remove electrical wires

First, clip the zip tie that is holding the four wires to the valves outside of the compressor.

cut ties