Keiser 1030, 1031 manual remove two screws on lid, pop out grommet

Models: 1031 1030

1 14
Download 14 pages 33.88 Kb
Page 4
Image 4
remove two screws on lid

Next, remove the lid to the computer control system box by unscrewing the screw on either side.

remove two screws on lid

Then remove the rubber grommet by using the needle nose pliers to carefully pop it out of the hole.

pop out grommet

Inside the computer control system box, cut all other zip ties holding the four wires. Trace each of the wires from the valve to the circuit board. There are two per valve, four wires total. The connectors are marked V1 and V2 on the circuit board. Remove each connector from the circuit board by pushing down on the board as you use the needle nose pliers to pull up on the connector. This allows you to safely remove the connectors without flexing or breaking the circuit board.

10-5508 Rev A

4

Service Department (800) 888-7009