PERFORMANCE DATA SHEET

Water Filtration System

Model P5WB2L/P4RFWB Capacity 200 Gallons (757 Liters)
@System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, and Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Live
Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction NSF Reduction Average Influent Challenge Maximum Average %
Aesthetic Effects Requirements Influent Concentration Effluent Reduction
Chlorine Taste/Odor 50% reduction 2.0 mg/L 2.0 mg/L +10% 0.20 mg/L ** 97.2
Particulate Class I* 85% reduction 7,300,000 #/mL At least 10,000 particles/mL 75,000 #/mL 99.4
Contaminant NSF Reduction Average Influent Challenge Maximum Average %
Reduction Requirements Influent Concentration Effluent Reduction
Live Cysts _ 99.95% 160,OOO/L 5O,OOO/Lmin. 54/U 99.99
Asbestos 99% 87 MFL 1OTto 1OSfibers/U _ 0.17 MFL 99
Lead: @pH 6.5 0.010 mg/L 0.160 mg/L 0.15 mg/L + 10% 0.001 mg/L 99.4
Lead: @pH 8.5 0.010 mg/L 0.140 mg/L 0.15 mg/L _+10% 0.005 mg/L 98.6
Lindane 0.0002 mg/L 0.0019 mg/L 0.002 mg/L _+10% 0.00002 mg/L 99
Toxaphene 0.003 mg/L 0.014 mg/L 0.015 mg/L _+10% 0.001 mg/L 93
Atrazine 0.003 mg/L 0.0094 mg/L 0.009 mg/L _+10% 0.0005 mg/L 94.7
2,4 - D 0.07 mg/L 0.220 mg/L 0.210 mg/L _+10% 0.028 mg/L 96.1
Test Parameters: pH : 7.5 ___0.5 unless otherwise noted. Flow -- 0.5 gpm (1.9 Lpm). Pressure = 60 psig
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
Minimum %
Reduction
97
99
Minimum %
Reduction
99.97
99
99.4
98.6
98.9
93
94.5
87.5
413.7 kPa).
It is essential that operational, maintenance, and filter The product is for cold water use only.
replacement requirements be carried out for the product to
perform as advertised.
Use replacement filter P4RFWB, part #9930.
2011 suggested retail price of $49.99 U.S.A./S59.99
Canada. Prices are subject to change without notice.
Style 1- When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter
indicator reads "REPLACE," it is recommended that you
replace the filter.
Style 2 -When the filter indicator changes from green to
yellow, order a new filter. When the indicator changes from
yellow to red, it is recommended that you replace the filter.
Style 3 -When the filter indicator reads 10%, order a new
filter. When the indicator reads 0%, it is recommended that
you replace the filter.
After changing the water filter, flush the water system. See
"Water and Ice Dispensers."
The water system must be installed in compliance with state
and local laws and regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be
used on disinfected waters that may contain filterable cysts.
Refer to the "Warranty" section for the Manufacturer's
name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33 ° _IO0°F (0.6 ° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary. %
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
tBased on the use of Cryptosporidium parvum oocysts
ttFibers greater than 10 um in length
® NSF is aregistered trademark of NSF International.
29