PERFORMANCE DATA SHEET

Water Filtration System

Model P5WB2L/P4RFWB Capacity 200 Gallons (757 Liters)

@System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, and Particulate

Class I*; and against NSF/ANSI Standard 53 for the reduction of Live Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The

concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the

permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance

Reduction

NSF Reduction

Average

Influent

Challenge

Maximum

 

Minimum

%

Average

%

Aesthetic

Effects

Requirements

Influent

Concentration

Effluent

 

Reduction

 

Reduction

Chlorine Taste/Odor

50%

reduction

2.0 mg/L

2.0 mg/L + 10%

0.20 mg/L

**

97

 

97.2

 

99

 

 

Particulate

Class I*

85%

reduction

7,300,000 #/mL

At least

10,000 particles/mL

75,000

#/mL

 

 

99.4

 

 

Minimum

%

 

Contaminant

NSF Reduction

Average

Influent

Challenge

Maximum

 

Average

%

 

Reduction

 

Reduction

 

Requirements

Influent

Concentration

Effluent

 

 

Reduction

 

 

 

 

 

 

Live Cysts _

99.95%

160,OOO/L

5O,OOO/Lmin.

54/U

 

 

99.97

 

99.99

 

Asbestos

 

99%

 

87 MFL

1OTto 1OSfibers/U _

0.17 MFL

 

99

 

99

 

Lead: @ pH 6.5

0.010

mg/L

0.160

mg/L

0.15

mg/L

+ 10%

0.001

mg/L

 

99.4

 

99.4

 

 

98.6

 

 

Lead: @ pH 8.5

0.010

mg/L

0.140

mg/L

0.15

mg/L

_+10%

0.005

mg/L

 

 

98.6

 

Lindane

 

0.0002 mg/L

0.0019

mg/L

0.002

mg/L

_+10%

0.00002 mg/L

98.9

 

99

 

 

 

 

 

Toxaphene

 

0.003

mg/L

0.014

mg/L

0.015

mg/L

_+10%

0.001

mg/L

 

93

 

93

 

Atrazine

 

0.003

mg/L

0.0094

mg/L

0.009

mg/L

_+10%

0.0005

mg/L

 

94.5

 

94.7

 

2,4 - D

 

0.07

mg/L

0.220

mg/L

0.210

mg/L

_+10%

0.028

mg/L

 

87.5

 

96.1

 

 

 

 

 

 

Test Parameters: pH : 7.5 0.5 unless otherwise noted. Flow -- 0.5 gpm (1.9 Lpm). Pressure = 60 psig 413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).

It is essential that operational, maintenance, and filter

replacement requirements be carried out for the product to perform as advertised.

Use replacement filter P4RFWB, part #9930.

2011 suggested retail price of $49.99 U.S.A./S59.99 Canada. Prices are subject to change without notice.

Style 1 - When the water filter status display changes from

"GOOD" to "ORDER," order a new filter. When the filter

indicator reads "REPLACE," it is recommended that you replace the filter.

The product is for cold water use only.

The water system must be installed in compliance with state and local laws and regulations.

Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be

used on disinfected waters that may contain filterable cysts.

Refer to the "Warranty" section for the Manufacturer's name, address and telephone number.

Style 2 - When the filter indicator changes from green to yellow, order a new filter. When the indicator changes from

yellow to red, it is recommended that you replace the filter.

Style 3 - When the filter indicator reads 10%, order a new

filter. When the indicator reads 0%, it is recommended that you replace the filter.

After changing the water filter, flush the water system. See "Water and Ice Dispensers."

These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. tBased on the use of Cryptosporidium parvum oocysts

ttFibers greater than 10 um in length

® NSF is a registered trademark of NSF International.

Refer to the "Warranty" section for the Manufacturer's limited warranty.

Application Guidelines/Water Supply Parameters

Water

Supply

City or Well

 

Water

Pressure

30 - 120 psi (207 - 827

kPa)

Water

Temperature

33 ° _ IO0°F (0.6 ° - 37.8°C)

Service

Flow Rate

0.5 gpm (1.9 Lpm) @ 60

psi

%

29

Page 29
Image 29
Kenmore 106.511800 Model P5WB2L/P4RFWB Capacity 200 Gallons 757 Liters, Application Guidelines/Water Supply Parameters