Kenmore 153.326661, 153.326761 Service and Adjustment contd, Drain Valve Washer Replacement

Models: 153.326361 153.32646 153.32676 153.32656 153.32666 153.326661 153.326461 153.326761 153.32636 153.32686 153.326861 153.326561

1 32
Download 32 pages 26.11 Kb
Page 20
Image 20
Element Cleaning/

Service and Adjustment (cont'd)

Element Cleaning/

Replacement (cont'd)

16.Replace terminal cover on thermostat making sure that the locking tabs on the terminal cover are in place.

17.Replace the insulation block and pad so that it completely covers the thermostat and element.

Drain Valve Washer

Replacement

NOTE: For replacement, use a _2" x _¾_" x _" thick washer

available at your nearest hardware store. For ordering a

replacement washer, refer to the "Parts Order List" section.

Before beginning turn "OFF" the electrical power supply to the water heater.

 

 

AWARNING

 

 

HAZARD OF ELECTRICAL SHOCK! Before removing

 

 

any access panels or servicing the water heater, make

 

 

sure the electrical supply to the water heater is turned

 

 

"OFF". Failure to do this could result in DEATH, SERI-

 

 

OUS BODILY INJURY,OR PROPERTY DAMAGE.

 

Follow "Draining" instructions. See "Service and Adjustment"

 

 

section.

 

 

• Turning counter clockwise, remove the hex cap below the

 

 

screw handle.

 

 

• Remove the washer and put the new one in place.

18.

Replace access panel.

 

 

 

• Screw the handle and cap a_ssemblyback into the drain valve

19.

Turn "ON" electric power to water heater.

and retighten using a wrench. DO NOT OVER TIGHTEN.

 

Follow "Filling the Water Heater" instructions in the

 

 

"Installation Instructions"

section.

 

Check for leaks.

 

 

_lhrn "ON" electric power

to the water heater.

Anode Rod Inspection

The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The sub- merged rod sacrifices itself to protect the tank. Instead of cor-

roding the tank, water ions attack and eat away the anode rod. This does not aftect the water's taste or color. The rod must be

maintained to keep the tank in operating condition.

Anode deterioration depends on water conductivity, not neces- sarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/or replaced more often than an anode rod that appears to be intact.

Replacement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by a Sears service technician, and at a minimum should be checked annually after the warranty period.

Service

Before calling for repair service, read the Start Up Conditions

and Operational Conditions found in the Troubleshooting Guide of this manual.

If a condition persists or you are uncertain about the operation of the water heater, let a qualified person check it out.

Contact SEARS Repair Services at 1-800-4-MY-HOME (1-800-469-4663).

20