Installation Instructions (cont'd)

Water Piping

*A WARNING

HOTTER WATER CAN SCALD: Water heaters are

intended to produce hot water. Water heated to a tem- perature which will satisfyspaceheating, clothes washing, dish washing, and other sanitizing needs can scald and _ermanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain tem- perature water at the hot water tap, then you must take special precautions. In addition to using the lowest possi- ble temperature setting that satisfies your hot water needs, a means such as a mixing valve, shall be used at the hot water taps used by these people or at the water

heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufacturers instructions for

installation of the valves. Before changingthe factory set- ring on the thermostat, read the "Temperature

Regulation" section in this manual.

HOT WATER A

COLD WATER

 

_

IN.LET

Installation completed

using

 

 

 

Installation

Kit

 

 

 

 

FLEXIBLE

 

SHUT-OFF

 

WATER

 

 

CONNECTORS

 

VALVE

 

HOT OUTLET

 

 

COLD

INLET

TO-HOUSE

t

 

WATER

LINE

 

\--

 

 

THREADED

TO

 

THREADED

TO

 

SWEAT COUPLING

SWEAT COUPLING

3/4" THREADED

__

 

3/4" THREADED

NIPPLE

_

 

NIPPLE

 

 

 

 

jTEHPERATURE.

 

 

_

RELIEF

VALVE

_PRESSURE

TEMPERED

WATEROUT' ' 2a

_fO COLD WATER

INLET ON

WATER HEATER

*MIXING VALVE WATER OUTLET

ON WATER HEATER

The illustration shows the attachment of the water piping to the water heater. The water heater is equipped with g" water connec- tions.

If a water heater is installed in a closed water supply system; such as one having a back-flow preventer, check valve, water meter with a check valve, etc. in the cold water supply; means shall be provided to

control thermal expansion. Contact the local utility or Sears Service Center on how to control this situation.

NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the cold water inlet connection. Do not solder the cold water supply line directly to the cold water inlet. It wRl harm the dip tube and damage the tank.

Look at the top cover of the water heater. The hot water outlet is marked hot. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends of the _" dlreaded nipple. Using flexible connectors, connect the hot water pipe to the hot water outlet of the water heater.

Look at the top cover of the water heater. The cold water inlet is marked cold. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around both ends of the _" threaded nipple. Using flexible connectors, connect the cold water pipe to the cold water inlet of the water heater.

NOTE: Yourwater heater is insulated to minimize heat loss from

the tank. Further reduction in heat loss can be accomplished by insulating the hot water lines from the water heater.

--DISCHARGEPIPE

(Do not cap or plug)

7 6" AIR GAP

FLOOR DRAIN

T&P Valve and Pipe Insulation

Remove insulation for T&P Valveand pipe connections from carton.

Fit pipe insulation over the incoming cold water line and the hot waterline. Make sure thattheinsula-

tion is against the top cover of the beaten

Fit T&P Valve insulation over valve. Make sure that the insulation does not interfere with the lever of the T&P valve.

Secure all insulation using tape.

Page 8
Image 8
Kenmore 153.326661, 153.326761, 153.326561 Installation Instructions contd, Water Piping, Valve and Pipe Insulation