Installation Instructions (cont'd)

3

ELBOW

EXAMPLE

MIN. RISEY¢'

PER FIVEFEET

MIN. RISEY;"

PER FIVEFEET

ALL MODELS (3" VENT)

See tables for max. length.

4'MiN.

157;'MIN.

14"MIN.

MIN, RISE¼"

 

 

PERFIVEFEET

1.The total vertical and horizontal vent run cannot exceed the maximum length with the number of 90 ° elbows as specified in the following tables. If more elbows are required, the vent- ing distance must be reduced 5 feet for every 90 ° elbow:

ALL MODELS-

VENTING

THROUGH

WALL

3" DIA.VENT

 

NUMBER

OF 90 ° DEG.

MAX. LENGTH

(FT.)

ELBOWS*

115

 

 

I

II0

 

 

2

105

 

 

3

100

 

 

4

95

 

 

5

9O

 

 

6

ALL MODELS- VENTING THROUGH WALL

OPTIONAL 2°" VENT PIPING

2" DIA.VENT

NUMBER OF 90 ° DEG.

MAX. LENGTH (FT.)

ELBOWS*

5O

I

45

2

4O

3

35

4

3O

5

25

6

*NOTE: Two 45 ° elbows are equivalent to one 90 ° elbow. One 90 ° elbow equals 5 feet of equivalent vent length.

_S'MAX.

MIN. RISEY;"

PERFIVE FEET

20'

ONE ELBOW

(EXAMPLE)

EXAMPLE

 

_l_ 3" VENT PIPE

EXAMPLE USING ONE ELBOW

WITH 3" VENT PIPE

2. Minimum vent length Gr all models is 4 feet.