APPROXIMATE SETTING TIME

Installation Instructions (cont'd)

APPROXIMATE SETTING TIME

FOR 2" TO 3" PIPE

INSTALLATION SHOWING USE OF PVC, ABS OR

JOINTS

 

CPVC PIPE

MOVEMENT

COMPLETE

 

 

 

OF

JOINT

SET

90°F

to

150°F

% hr.

8 hrs.

50°F

to

90°F

I hr.

15 hrs.

_. EXTERIOR

SEALER _// _"_ WALL

HIN EXTENSION

......THROUG H

0°F to 50°F

1% hr.

18 hrs.

SILICONE

J_ _

EXTERIOR WALL

 

 

 

 

_/

_

SCREW

CUTTING OPENING THROUGH AN OUTSIDE

WALL AND COLLAR INSTALLATION

After reading the manual and you have determined the location

of the op,eningin the wall, (using the draw!ng below), cut a 2_" hole for 2 vent piping or a 3_' hole for 3 vent piping through an exterior wall.

NOTE: When determining location of the opening in the outside wall allow for the ¼° rise per five feet that has taken

place in the horizontal run.

" '" ""

I N

PER FIVE FEET

L

 

 

40 GAL.- 59½"

50 GAL.- 6(7'

N

The 3" (or optional 2") PVC, ABS, or CPVC Schedule 40 vent pipe can be run from the water heater through the wall or from the wall to the water heater, whichever is most convenient. The vent pipe must extend a minimum of 1_" through the exterior wall. Extending the vent cap as far as possible from the surface of the exterior wall will help minimize discoloration of the wall in this area which may be caused by the flue gases. Note that the inside collar must be slipped over the vent piping before locat- ing the pipe through the wall. Before securing the inside and outside collars to the wall, use a silicone sealer between pipe and opening to insure a water and air tight seal.

 

 

VENT CAP MUST

SEALER

_

BE POSITIONIED

 

/

DOWNWARD

CONNECTING PVC, ABS OR CPVC PIPE VENT TO

BLOWER

1.If making an immediate horizontal run of vent off'the blower, a Y' PVC, ABS or CPVC Schedule 40 (supplied locally) elbow is required. Place the elbow in the required direction on the blower and using 3 sheet metal screws, attach the elbow.

SEAL WITH

_

_

_" _"

I

2.If there is to be a vertical run of vent from the blower, the Y'

PVC, ABS or CPVC pipe must be attached to the blower using 3 sheet metal screws.

SEAL WITH

 

 

RTV SEALANT

_

_"

3.If the optional 2" ventpiping is to used, the 2" street elbow, Y' to 2" reducer and Y' (minimum) section of 3" PVC, ABS or

CPVC pipe must be supplied locally.The 3" (minimum) section of 3' PVC, ABS or CPVC p'pe must be attached to the blower using 3 sheet metal screws.