Tank (Sediment) C_eaning

Tank (Sediment) C_eaning

Sediment build-up on the tank bottom may create varying amount of noise, and if left in the tank will cause permanent tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank. In these cases Mag-Erad (part no. 23600) can be used to help remove

the sediment deposits. This may be ordered from the Sears

Service Center. For ordering, refer to the Parts Order List section.

Vent System _nspection

Carbon Monoxide and Fire Hazard

Flue gases may escape if vent pipe is not connected.

o Be alert for obstructed, sooted or

deteriorated vent system to avoid serious injury or death.

Do not store corrosive chemicals in vicinity of water heater.

Chemical corrosion of flue and vent

system can cause serious injury or death

Burner Inspection

Flood damage to a water heater may not be readily visible or

immediately detectable. However, over a period of time a

flooded water heater will create dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Contact a Sears Service Center to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!

At least once a year a visual inspection should be made of the main burner and pilot burner, see Figure 23.

You should check for sooting. Soot is not normal and will impair proper combustion.

Soot build-up indicates a problem that requires correction before further use. Turn 'OFF" gas to water heater and leave off until repairs are made, because failure to correct the cause of the sooting can result in a fire causing death, serious injury, or property damage.

FIGURE23.

Breathing carbon monoxide can cause brain damage or death Ak_ays read and understand instruction manual

Burner C_eaning

At least once a year a visual inspection should be made of the venting system. You should look for:

Obstructions which could cause improper venting. The

combustion and ventilation air flow must not be obstructed.

Damage or deterioration which could cause improper

venting or leakage of combustion products.

Rusted flakes around top of water heater.

Be sure the vent piping is properly connected to prevent escape

of dangerous flue gasses which could cause deadly asphyxiation.

Obstructions and deteriorated vent systems may present serious health risk or asphyxiation.

Chemical vapor corrosion of the flue and vent system may

occur if air for combustion contains certain chemical vapors.

Spray can propellants, cleaning solvents, refrigerator and air

conditioner refrigerants, swimming poo! chemicals, calcium and sodium chloride, waxes, bleach and process chemicals

are typical compounds which are potentially corrosive.

If when inspecting the vent system you find sooting or

deterioration, something is wrong_ Call the local gas supplier to correct the problem and clean or replace the flue and venting before resuming operation of the water heater.

Fire or Explosion Hazard

Failure to properly reseal the combustion chamber will disable the flammable vapor ignition resistance feature of this water heater, which could result in death or serious

injury Contact your local Sears Service Center for assistance

Read instruction manual before

installing, using or serwcmg

water heater,

In the event your burner needs cleaning, following these instructions:

If inspection of the burner shows that cleaning is required, turn

the gas control knob clockwise ( r'_ ) to the 'OFF" position,

depressing slightly.

NOTE: The knob cannot be turned from "PmLOT" to "OFF"

unless knob is depressed siightmy. DO NOT FORCE.

The burner needs to be removed for cleaning. Cal! the Sears Service Center to remove and clean the burner and correct the problem that required the burner to be cleaned.

2O

Page 20
Image 20
Kenmore 153336862, 153.336262, 153336762 Tank Sediment C_eaning, Vent System _nspection, Burner Inspection, Burner C_eaning