AbbreviationsFoundInThisInstructionManual:

ThankYouforpurchasingKenmorewaterheaterProperly. installedandmaintained,it shouldgiveyouyearsoftrouble freeserviceIfyoushoulddecidethatyouwantthenewwater. heaterprofessionallyinstalledbySearscall1-800-4+MY-HOME®.

Theywillarrangefor prompt,qualityinstallationbySears authorizedcontractors.

AbbreviationsFoundInThisInstructionManual:

The installation must conform with these instructions and

the local code authority having jurisdiction. In the absence of

local codes, installations shall comply with the following:

In the United States: The National Fuel Gas Code ANSI

Z223.1/NFPA 54+ This publication is available from the

Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The Nationa! Fire Protection

Association, 1 Batterymarch Park, Quincy, MA 02269.

CSA- CanadianStandardsAssociation

ANSI- AmericanNationalStandardsInstitute

NFPA-NationalFireProtectionAssociation

ASME-AmericanSocietyofMechanicalEngineers

GAMA- Gas Appliance Manufacturers Association

This gas-fired water heater is design certified by CSA

INTERNATIONAL under American National Standard/CSA Standard for Gas Water Heaters ANSI Z21.10.1 • CSA 4.1 (current edition).

Read the "Safety Precautions" section, page 3 of this manual first and then the entire manual carefully+ If you don't follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation,

operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of+ All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

If after reading this manual you have any questions or do not

understand any portion of the instructions, call the Sears Service Center.

Carefully plan the place where you are going to put the water

heater. Correct combustion, vent action, and vent pipe

installation are very important in preventing death from

possible carbon monoxide poisoning and fires. See figure 1.

Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual.

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an

earthquake. See instructions for correct installation

procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the

State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be

installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.

Complies with SCAQMD rule #1121 and districts having

equivalent NOx requirements.

 

 

 

 

 

RECOVERY

MiNiMUM

 

 

DIMENSIONS

 

TANK

TYPE

iNPUT

RATE

GALS

VENT

PiPE

DIAMETER

iN iNCHES

(rein}

MODEL

CAPACITY

OF

RATE

PER

HOUR

iNCHES

iNCHES

HEIGHT

TO

NUMBER

N GALS (LTRS

GAS

(Btu/hr)

@ 9G°F RISl

(ram)

 

(ram)

JACKET

 

TOP

153.336162

30 (114)

NATURAL

32,000

 

30.6

3" (76) or

4" (!02)

18

1/2" (470)

43 3/4"

(1,!11)

153.336262

40

(! 51 )

NATURAL

35,500

 

35.4

3" (76) or

4" (102)

20" (508)

47

1/4"

(1,200)

153.336362

30 (114)

NATURAL

35,500

 

34.9

3" (76)

16" (406)

57

1/2"

(I ,461 )

153.336466

40

(! 51 )

NATURAL

35,500

 

35.4

3" (76)

18

1/2" (470)

55 1/2"

(1,41 O)

153.336566

50

(! 89)

NATURAL

35,500

 

35.4

3" (76)

20" (508)

56

1/2"

(! ,435)

153.336762

30 (114)

PROPANE

35,500

 

34.9

3" (76)

16" (406)

57

1/2"

(! ,461 )

153.336862

40

(!51)

PROPANE

35,500

 

35.4

3" (76)

18

1/2" (470)

55

1/2"

(! ,410)

153.336962

50 (! 89)

PROPANE

35,500

35.4

3" (76)

20" (508)

56 1/2" (! ,435)