Filling the Water Heater

Thetemperatureopressurereliefvalvemustbe manually operated leastoncea year. Cautionshouldbetakento ensurethat(1)nooneisinfrontoforaroundtheoutletofthe temperatureopressurereliefvalvedischargeline,and(2)the watermanuallydischargedwillnotcauseanybodilyiniuryor propertydamagebecausethewatermaybeextremelyhot.

Ifaftermanuallyoperatingthevalve,itfailstocompletelyreset andcontinuesto releasewater,immediatelyclosethecold waterinlettothewaterheater,followthedraininginstructions, andreplacethetemperatureopressurereliefvalvewitha new

one,

Filling the Water Heater

Property Damage Hazard

-Avoid water heater damage_

-Fill tank with water before operating.

Never use this water heater unless it is completely full of water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning "ON" gas to the water heater.

To fill the water heater with water:

Close the water heater drain valve by turning the handle to the right (clockwise). The drain valve is on the lower front of the water heater.

Open the cold water supply valve to the water heater.

NOTE: The cold water supply vaJve must be left open when the water heater is in use.

To insure complete filling of the tank, allow air to exit by

opening the nearest hot water faucet Allow water to run

until a constant flow is obtained. This will let air out of the water heater and the piping.

Check all water piping and connections for leaks. Repair as needed.

Venting

and mechanically actuated vent dampers). Before installation of any vent damper, consult your local Sears Service Center or the local gas supplier for further information.

Breathing Hazard - Carbon Monoxide Gas

°Vent dampers must be certified in accordance with ANSI Z21.68.

Vent damper must permit proper drafting of water heater

. Install propedysizedventing

Do not install without venting outdoors

o Do not install without drafthood.

If common vented install in accordance with NFPA 54,

. Be alert for obstructed or deterio-

rated vent system to avoid serious injury or death.

Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual,

To insure proper venting of this gasofired water heater, the correct vent pipe diameter must be utilized. Any additions or deletions of other gas appliances on a common vent with this water heater may adversely affect the operation of the water

heater. Consult your gas supplier if any such changes are

planned. For replacement heater installations where using preo

existing venting, venting must be inspected for obstructions

and if deterioration is present, venting must be replaced.

For proper venting in certain installations, a larger diameter

vent pipe may be necessary. Consult your local Sears Service

Center or gas supplier to aid you in determining the proper venting for your water heater from the vent tables in the current

edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54.

Periodically check the venting system for signs of obstruction

or deterioration and replace if needed.

The combustion and ventilation air flow must not be obstructed.

The water heater with draft hood installed must be connected to a chimney or listed vent pipe system, which terminates to the outdoors. Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation, explosion or asphyxiation.

VENT DAMPERS o Any vent damper, whether it is operated thermally or otherwise must be removed if its use inhibits proper drafting of the water heater.

Thermally Operated Vent Dampers: Gasofired water heaters

having thermal efficiency in excess of 80% may produce a

relatively low flue gas temperature. Such temperatures may not be high enough to properly open thermally operated vent

dampers. This would cause spillage of the flue gases and may cause carbon monoxide poisoning.

Vent dampers must bear evidence of certification as complying

with the current edition of the American National Standard ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically

For proper draft hood attachment, the draft hood legs may be angled slightly inward.

Place the draft hood legs in the receiving holes on the top of the water heater. The legs will snap in the holes to give a tight fit. Secure two legs to top with sheet metal screws.

Place the vent pipe over the draft hood. With the vent pipe in position, drill a small hole through both the vent pipe and draft hood. Secure them together with a sheet metal screw, see Figure 17.

Obstructed or deteriorated vent systems may present serious health risk or asphyxiation.