Kenmore 153336566, 153.336262, 153336762, 153.336962 Waterleaks, Smellyodors, Leakingt&Pvalve

Models: 153336762 153336362 153336466 153.336962 153.336262 153336566 153336862 153336162

1 32
Download 32 pages 19.76 Kb
Page 26
Image 26
WATERLEAKS

TheseguidelinesshouldbeusedbyaqualifiedserviceagentCallSearsServiceat1.-800o4oMYoHOME'(Io800; -469-4663) forassistance,informtheassociatethatthisisa"FlammableVaporignitionResistant"Product.

WATERLEAKS

LEAKINGT&PVALVE

SMELLYODORS

PILOT WILL NOT L_GHT

BURNER WILL NOT

STAY UT

PILOT OUTAGE

NOT ENOUGH

HOT WATE R

Improperly sealed, hot or cold supply connection, relief valve, drain valve, or thermostat threads. Leakage from other appliances or water lines. Condensation of flue products.

Thermal expansion in closed water system. Improperly seated valve.

High sulfate or mineral content in water supply.

Bacteria in water suppty.

Gas controt knob not positioned correctly. Main gas supply off.

Igniter tip more than 1/8" from pilot hood. Thermocouple malfunction.

Thermocouple TCO malfunction.

Melted insulation on igniter wire or shorting of igniter wire.

High ambient room temperature.

Wire disconnected from spark igniter.

Broken electrode or electrical wire.

Piezo tgniter generator fails to operate or malfunctions.

Thermocouple TCO malfunction.

High ambient room temperature.

Dirty or ctogged air intake screen.

Flame arrestor openings blocked.

Defective Gas Control.

Dirty pilot burner.

Dirty or clogged air intake screen.

Thermocouple tip is not in contact with pilot flame. Thermocouple malfunction.

Thermocouple TCO malfunction.

Defective Gas Control.

Heater not tit or thermostat not on.

Thermostat set too low.

Heater undersized.

Low gas pressure.

Incoming water is unusually cold. Leaking hot water pipes or fixtures. High temperature limit switch activated.

Tighten threaded connections.

Inspect other appliances near water heater. Refer to CONDENSATION.

install thermal expansion tank (DO NOT plug T&P valve). Check relief valve for proper operation

(DO NOT plug T&P valve).

Drain and flush heater thoroughly, then refill.

Chlorinate or aerate water supply.

Refer to LIGHTING INSTRUCTIONS.

Turn on main gas shutoff valve.

Adjust igniter tip.

Replace pilot assembly.

Reptace pilot assembly.

Contact Sears Service to determine cause.

Contact Sears Service to determine cause.

Reconnect wire connector to spark igniter. Replace pilot assembly.

Replace Piezo Igniter generator.

Reptace pilot assembly. Contact a service agency to determine cause.

Ctean and reinstall air intake screen. Contact Sears Service to determine cause.

Replace Gas Control.

Clean pilot assembly.

Clean and reinstall air intake screen.

Insert thermocoupIe correctly.

Replace pilot assembly.

Replace pilot assembly.

Replace Gas Control.

Refer to LIGHTING INSTRUCTIONS.

Refer to TEMPERATURE REGULATtON.

Reduce hot water use.

Contact your gas supplier.

Allow more time for heater to re-heat.

Have plumber check and repair leaks.

Contact Sears Service to

determine cause.

WATER TOO HOT

WATER HEATER SOUNDS

StZZLING o RUMBLBNG

SOOTING

VENTGASODORS

Thermostat set too high. Condensation dripping on burner.

Sediment or calcium in bottom of heater tank.

Improper combustion.

Lack of supply air.

Improperly installed vent piping.

Downdraft.

Poor combustion.

Refer to TEMPER_,TURE REGULATION. Refer to CONDENSATION.

Clean sediment from tank. Refer to DRAINtNG instructions in Maintenance section of manual. No adjustment available. Contact Sears Service to determine cause.

Contact Sears Service to determine cause.

26

Page 26
Image 26
Kenmore 153336566, 153.336262, 153336762, 153.336962, 153336862, 153336466, 153336362 Waterleaks, Smellyodors, Leakingt&Pvalve