PREPARE THE HOOD

1. Lay the hood on its back on a table.

Remove grease filters by lifting the metal latch tab (1),

pushing down on the filter (2) and tilting is towards you (3).

NOTE

Use a piece of cardboard to avoid damaging the table or the

hood.

3

1

2

HD0376

2.Choose the opening:

VERTICAL DISCHARGE:

Using a Robertson or a Phillips no. 2 screwdriver, remove the 4 top metal plate retaining screws in order to clear the vertical discharge opening (see illustration beside). Discard the metal plate and its screws.

RETAINING SCREWS LOCATIONS

HO0142

Warranty

Safety

Operation

HORIZONTAL DISCHARGE:

In order to ease a retrofit installation, the horizontal discharge may be positioned on higher OR on lower back of the hood. From outside the unit, remove the knockout for the chosen discharge opening (see illustrations beside).

1

2

OR

OR

HR0038

 

Cleaning

Installation

Service Parts

9

Page 9