_i_ii_ii_i_SECTION 5 i_i_i_i_iii_i_i] SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
MANUAL ADVANCE REGENERATION CHECK
This check verifies proper operation of the valve
motor, brine tank fill, brine draw, regeneration flow rates, and other controller functions. Always make
the initial checks, and the manual initiated diag- nostics.
Notes:
The faceplate display must show a steady time (not flashing). If an error code shows, first press the SE-
LECT button to enter the diagnostic display.
_q | Press | the |
| button | and hold | in for | ||||
| 3 seconds. *RECHARGE and Fill begin to flash | |||||||||
| (or clean | backwash | begins, if set) as the softener | |||||||
| enters | the | fill | cycle | of regeneration. |
| When | FILL is | ||
| on steady, remove the brinewell cover and, using | |||||||||
| a flashlight, observe fill water entering the tank. | |||||||||
| *Note: |
|
|
|
|
|
|
|
|
|
| If the CLEAN feature is set to ON, a cleaning back- | |||||||||
| wash (CLEAN and Bkwsh or Rinse flashes in the dis- | |||||||||
| play, along with the minutes of the clean cycle re- | |||||||||
| maining), | precedes | the recharge. |
|
|
| ||||
| a. If water does not enter the tank look for an ob- | |||||||||
| structed nozzle, venturi, fill flow plug, brine tubing, | |||||||||
| or brine valve riser pipe. |
|
|
|
| |||||
|
|
|
|
| UltraSoft | 250 |
|
|
| |
| CYCLE FLOW RATES (GALLONS PER MIN.) | |||||||||
| FILL (flow to salt storage tank) | 0.3 | (1.1 | liters) |
| |||||
| BRINING |
| _ |
|
| .15 | ||||
| BACKWASH |
|
| to |
| 1.8 | (6.8 | liters) |
| |
|
| I | drain) | .11 | (.45 | liters) |
| |||
| BRINE | RINSE | (flow |
| ||||||
| FAST RINSE |
|
|
| 1.8 | (6.8 | liters) |
| ||
|
|
|
|
| UltraSoft | 275 |
|
|
| |
| CYCLE FLOW RATES (GALLONS PER MIN.) | |||||||||
| FILL (flow to salt storage tank) | 0.3 | (1.1 | liters) |
| |||||
| BRINING |
| '_ |
|
| .21 | (.79 | liters) |
|
Note:
Be sure a salt bridge is not preventing water with salt contact.
a. If the softener does not draw brine ...
• ...nozzleand/orventuridirtyordefective.Seepage
•..nozzle and venturi not seated properly on gasket.
See page
...restricted drain (check drain fitting and hose).
...defective nozzle and venturi seal. See page
...other inner valve defect (rotor seal rotor & disc, wave washer, etc.).
Note: If water system pressure is low, an elevated
drain hose may cause back pressure, stopping brine draw.
[]Again | press | to | move | the soft- | |
ener | into | backwash. Look for | a fast | flow | of water |
from | the | drain hose. |
|
|
|
a. An obstructed flow indicates a plugged top dis-
tributor, backwash flow plug, or drain hose.
[ Press
nBRINE VALVE
,.FLOAT SETTING
BACKWASH | to | 2.0 | (7.6 | liters) | |
drain) | .15 | (.57 | liters) | ||
BRINE | RINSE | I (flow | |||
FAST | RINSE |
| 2.0 | (7.6 | liters) |
_ After observing fill, press the
button to move the softener into brining. A slow flow of water to the drain will begin. Verify brine draw from the brine tank by shining a flashlight
into the brinewell and observing a noticeable drop in the liquid level.
Problems, Questions? Call