Kenmore 10656714500, Elite, 10656719500 Product Data Sheet, Base Grille Water Filtration System

Models: 10656712500 10656702500 10656703500 10656704500 10656706500 10656709500 10656714500 10656716500 10656713500 10656719500 Elite

1 80
Download 80 pages 26.09 Kb
Page 26
Image 26
PRODUCT DATA SHEET

PRODUCT DATA SHEET

Base Grille Water Filtration System

Model TIKB1/TIRFKB1 Capacity 100 Gallons (379 Liters)

 

Chlorine

Taste

and

Odor, Particulate

Class

I*; and

against NSF/ANSl

Standard

53

for

the reduction of

(_

I Tested

and certified

by

NSF International

against

NSF/ANSI Standard

42

for

the

reduction of

 

Lead,

Mercury,

Atrazine,

Benzene,

Toxaphene,

O-Dichlorobenzene,

Cysts,

Turbidity,

Asbestos,

 

L ndane,

Tetrach oroethy

ene, Endr

n, A ach or,

Ch

orobenzene, Ethy benzene, TTHM and MTBE.

This system has been tested according to NSF/ANSl 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSl 42/53.

Substance

Reduction

NSF Reduction

Average

Influent

Challenge

Maximum

Average

Minimum

%

Average

%

Aesthetic

Effects

Requirements

Influent

 

Concentration

Effluent

Effluent

Reduction

 

Reduction

Chlorine Taste/Odor

50%

reduction

2.0

mg/L

2.0 mg/L

_+10%

0.08

mg/L

2.0

mg/L

95.93

 

97.36

 

Particulate

Class I*

85%

reduction

3533333#/mL

At east 10,000 part c es/mL

22000

#/mL**

11567

#/mL

99.38

 

99.67

 

Contaminant

 

NSF Reduction

Average

Influent

Challenge

Maximum

Average

Minimum

%

Average

%

Reduction

 

Requirements

Influent

 

Concentration

Effluent

Effluent

Reduction

 

Reduction

Lead: @ pH 6.5

0.010

mg/L

150 ug/L

0.15

mg/L

_+10%

1.0

ug/L

1 ug/L

 

99.33

 

99.33

 

Lead: @ pH

8.5

0.010

mg/L

157 ug/L

0.15

mg/L

_+10%

2.0

ug/L

1.08

ug/L

98.72

 

99.31

 

Mercury:

@ pH 6.5

0.002

mg/L

0.0058

mg/L

0.006

mg/L

_+10%

0.0002

mg/L

0.0002

mg/L

96.53

 

96.53

 

Mercury:

@ pH 8.5

0.002

mg/L

0.0057

mg/L

0.006

mg/L

_+10%

0.0002

mg/L

0.0002

mg/L

96.5

 

96.5

 

Benzene

 

 

0.005

mg/L

15 ug/L

 

0.015

mg/L

_+10%

0.5

ug/L

0.5

ug/L

96.67

 

96.67

 

O-Dichlorobenzene

0.6 mg/L

1750 ug/L

1.8 _+10%

 

1.0

ug/L

1.0

ug/L

99.94

 

99.94

 

Toxaphene

 

0.003

mg/L

15 ug/L

 

0.015

_+10%

1.0

ug/L

1.0 ug/L

93.33

 

93.33

 

Atrazine

 

 

0.003

mg/L

10 ug/L

 

0.009

mg/L

_+10%

2 ug/L

 

2 ug/L

 

80.8

 

80.8

 

Asbestos

 

 

99%

 

101 MFL

107to

108fibers/L *t

0.17

MFL

0.17

MFL

99.83

 

99.83

 

Live Cysts*

 

>99.95%

120,000/L

50,000/L

min.

8/12

 

 

l/L*

 

 

99.99

 

>99.99

 

Turbidity

 

 

0.5 NTU

11.4 NTU

11 _+1 NTU

0.41

NTU

0.24

NTU

96.4

 

97.89

 

Alachlor

 

 

0.002

mg/L

41.3

ug/L

0.04

_+10%

0.2

ug/L

0.2 ug/L

99.52

 

99.52

 

Endrin

 

 

0.002

mg/L

5.9

ug/L

0.006

_+10%

0.5

ug/L

0.3

ug/L

91.5

 

95.47

 

Ethylbenzene

 

0.7 mg/L

1867 ug/L

2.1 _+10%

 

0.70

ug/L

0.0588

ug/L

99.96

 

100

 

Lindane

 

 

0.002

mg/L

1.9

ug/L

0.002

_+10%

0.02

ug/L

0.02

ug/L

98.93

 

98.93

 

Chlorobenzene

0.6 mg/L

2.0

ug/L

2.0 _+10%

 

0.0005

ug/L

0.0005

ug/L

99.98

 

99.98

 

Tetrachloroethylene

0.005

mg/L

14.2 ug/L

0.015

_+10%

0.5

ug/L

0.5

ug/L

96.47

 

96.47

 

TTHM

 

 

0.080

mg/L

465

ug/L

0.45

_+20%

1.0

ug/L

0.5

ug/L

99.78

 

99.88

 

MTBE

 

 

0.005

mg/L

14 ug/L

 

0.015

_+20%

0.70

ug/L

0.52

ug/L

94.94

 

96.27

 

Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

Model T1KB1 : The filter monitor system measures the amount of

water that passes through the filter and alerts you to replace the filter.

Style 1 - When the filter indicator reads 10%, order a new filter. When the filter indicator reads 0%, it is recommended that you replace the filter.

Style 2 - When the filter indicator light changes from green to yellow, order a new filter. When the filter indicator light changes from yellow to red, it is recommended that you replace the filter.

Use replacement cartridge T1RFKB1, part #9020. In Canada, use replacement cartridge T1RFKB1, part #9020B. 2005 suggested retail price of $39.99 U.S.A./S59.95 Canada. Prices are subject to change without notice.

These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.

The product is for cold water use only.

Refer to the front cover or "Accessories" section for the Manufacturer's name, address and telephone number.

Refer to the "Warranty" section for the Manufacturer's limited warranty.

 

Application

Guidelines/Water

Supply

Parameters

Water

Supply

City

or Well

 

Water

Pressure

30

- 120

psi

(207 - 827 kPa)

Water

Temperature

33 ° - 100°F

(0.6 ° - 37.8°C)

Service

Flow Rate

0.5

gpm

(1.9

L/min) @ 60 psi

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. tfFibers greater than 10 um in length

*Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.

26

Page 26
Image 26
Kenmore 10656714500, Elite, 10656719500, 10656713500, 10656716500 Product Data Sheet, Base Grille Water Filtration System