BATTERY SAVER
Battery Saver repeats switching the receive circuit ON
and OFF at a certain interval when no signal is present
and no key is pressed for approximately 10 seconds.
This function becomes passive whenever a signal is
received or any key is pressed.
Access Menu 1–2–1 (BAT SAVER) to select the desired
interval (power OFF duration). The default is 1.0
second.
The selectable intervals are 0.2, 0.4, 0.6, 0.8, 1.0, 2.0, 3.0,
4.0, and 5.0 seconds plus OFF; selecting OFF switches the
function OFF.
AUTOMATIC POWER OFF (APO)
Automatic Power Off is a background function that
monitors whether any keys have been pressed, or
whether any control has been turned. After the
predetermined time passes with no operations, APO
turns OFF the power. However, 1 minute before the
power turns OFF, “APO” blinks and a series of warning
tones sound.
Access Menu 1–2–2 (APO) and select 30 minutes
(default), 60 minutes, or OFF.
Note:
If a signal is received while APO is ON, the timer begins counting
again from 0.
The APO timer does not operate while Tone Alert or any scan is being
used.