To prevent heat damage to the fill valve, ALL solder connections must be made BEFORE the water line

is connected to the dishwasher.

.

DRAIN LINE

The drain line should be 9/,6” (14 mm) ID (minimum) flexible hose or 5,‘~”(16 mm) OD copper tubing. Flexible hose must be resistant to heat and detergent and may be obtained from a plumbing, hardware, or automotive supply outlet. DO NOT use any fittings anywhere in the drain line that are less than l/2” (13 mm) ID. The access hole for the drain line should be 1’ (25 mm).

If drain line is copper, clamp a 12” (305 mm) length of g/16” (14 mm) ID flexible hose (heat and detergent resistant) to the end of the copper tubing. This will facilitate connection of the drain line to dishwasher check valve.

If the drain line is going to be connected to a food waste disposer, BE SURE to remove the knockout or plug from the fitting on the disposer before connecting drain line. Rubber adapter fitting may be required. (KitchenAid part number 115739 or available from local hardware or plumbing stores.)

Typical drain connections to sink plumbing are shown in Fig. 5 & 6.

Dra ‘1or disposer connectlon

Air Gap

~~ --y-- --- ~~~-__

 

II

J , I ‘LJ

k--IL

“If &a,” hne IS flex;bie-hose lhls dlmenslon IS

22” (559 mm)

If drain line IS copper. the copper should be 12” (305 mm) plus a 12” (305 mm) length of flexible hose attached to Ihe end

IIdrain lme IS copper, the copper should be 12” (305 mm) plus a 12” (305 mm) lenglh of flextble hose attached lo the end

_

4”

Fig. 5

 

Fig. 6

(108

r7m;

(;84r&rn)

Typlcal drain connection

to an air gap (If required

by local code) IS shown in Fig. 6.

 

IF DRAIN IS ROUTED TO A CONNECTION POINT LESS THAN 20” (508 mm) ABOVE THE FLOOR, THE DRAIN LINE MUST BE MADE TO FORM A HIGH LOOP TUBE (SHOWN IN FIG. 7).

FAILURE TO PROVIDE EITHER THE PROPER DRAIN CONNECTION HEIGHT (20” (508 mm) ABOVE FLOOR LEVEL) OR A 20” (508 mm) HIGH LOOP WILL RESULT IN IMPROPER DRAINING OF THE MACHINE WHICH MAY CAUSE DAMAGE TO THE MACHINE.

TO FORM THE HIGH LOOP TUBE, SEE INSET ON FIG. 7. MAKE SURE THAT NO KINKS DEVELOP IN THE HOSE OR COPPER TUBING.

VB” (16 mm) O.D. Copper tubing must be at least 20” (506 mm)

I above floor.

‘If drain line IS flexible hose this dlmenslon IS

22” (559 mm)

If drain line IS copper, the copper should be 12” (305 mm) plus a 12” (305 mm) length of flexible hose allached 10 Ihe end

- a"-

(108 mm) Fig. 7

Page 7
Image 7