ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE CANADIAN ELECTRICAL CODE AND/OR OTHER LOCAL CODES.

DISCONNECT ELECTRICAL POWER SUPPLY.

TOt? electrical supply must be a 115 volt, 15 amp, properly grounded, positloned as shown in Fig. 8, and should be Installed by a qualified electrician. No other appliances or outlets should be on this circuit.

-+I 3” I-

176mm)

Fig. 0

To access dishwasher connections:

Remove the two screws located on each side and below the lower panel. Pull out the bottom of the panel to unhook tabs from frame. Lift the panel up and off. Set aside. Pull adjustable kickboard straight off.

5

Adjustable klckboard

Fig. 9

3 PLACING THE DISHWASHER IN ITS LOCATION

The adjustable klckboard and lower panel (Fig. 9) must be removed for access to dishwasher connections. Remove the kickboard (5) by removing the two screws (one with lock washer) that secure it. Remove two screws (1) and pull out the bottom of lower panel to unhook tabs (2) from frame. Remove the lower panel by pulling it downward tO slide panel flanges (3) from behind the support channel (4).

Set ?he dishwasher if-: front of the orepared cabinet opening and evenly adjust the four leveling feet to the desired herqh!