Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Do not obstruct flow of combustion and ventilation air.

It is the installer’s responsibility to comply with installation

clearances specified on the model/serial rating plate. The

model/serial rating plate is located behind the control panel

and may be rotated up from behind the control panel for

viewing from the front of the range.

The range should be located for convenient use in the

kitchen.

Recessed installations must provide complete enclosure of

the sides and rear of the range.

To eliminate the risk of burns or fire by reaching over heated

surface units, cabinet storage space located above the

surface units should be avoided. If cabinet storage is to be

provided, the risk can be reduced by installing a range hood

or microwave hood combination that projects horizontally a

minimum of 5" (12.7 cm) beyond the bottom of the cabinets.

All openings in the wall or floor where range is to be installed

must be sealed.

Do not seal the range to the side cabinets.

Cabinet opening dimensions that are shown must be used.

Given dimensions are minimum clearances.

The anti-tip bracket must be installed. To install the anti-tip

Product Dimensions

B*

C**

A**

D

bracket shipped with the range, see “Install Anti-Tip Bracket”

section.

Grounded electrical supply is required. See “Electrical

Requirements” section.

F

E***

Proper gas supply connection must be available. See “Gas

Supply Requirements” section.

Contact a qualified floor covering installer to check that the

floor covering can withstand at least 200°F (93°C).

Use an insulated pad or ¼" (0.64 cm) plywood under range if

installing range over carpeting.

A. 35³⁄₄" ± ¹⁄₈" (90.8 ± 0.3 cm) cooktop height (minimum) with leveling legs screwed all the way in**

B. Model/serial/rating plates (located behind the control panel)*

C. 47¹⁄₈" ± ¹⁄₈" (119.7 ± 0.3 cm) overall height (minimum) with leveling legs screwed all the way in**

D. 28¹⁄₂" ± ¹⁄₄" (72.4 ± 0.6 cm) depth with handle

E. 26¹⁄₈" ± ¹⁄₈" (66.4 ± 0.3 cm)***

F. 29¹⁵⁄₁₆" ± ¹⁄₁₆" (76.0 ± 0.2 cm) width

IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.

In Canada, the installation of this range must conform with the current standards CAN/CSA-A240-latest edition, or with local codes.

Mobile home installations require:

When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.

Four-wire power supply cord or cable must be used in a mobile home installation. The appliance wiring will need to be revised. See “Electrical Connection - U.S.A. Only” section.

*Model/serial/rating plates may be rotated up from behind the control panel for viewing from the front of the range.

**Range can be raised approximately 1" (2.5 cm) by adjusting the leveling legs.

***Excludes handle. Dimension given is from wall to front of oven door and will vary based on electric outlet receptacle installation.

Cabinet Dimensions

Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height.

IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.

Range may be installed with zero clearance to combustible construction at the rear and on the sides below the cooktop.

4

Page 4
Image 4
KitchenAid W10526086A Location Requirements, Product Dimensions, Mobile Home Additional Installation Requirements