3.Pull the conduit through the strain relief on cord/conduit plate on bottom of range. Allow enough slack to easily attach wiring to the terminal block.
A
B
| C |
G | D |
| |
F | E |
| |
A. Terminal block | E. Neutral (white) wire |
B. | F. Line 1 (black) wire |
C. Cord/conduit plate | G. Bare (green) ground wire |
D. Line 2 (red) wire |
|
4.Attach terminal lugs (located in the package containing literature) to line 1 (black), neutral (white), and line 2 (red) wires. Loosen (do not remove) the setscrew on the front of the terminal lug and insert exposed wire end through bottom of terminal lugs. Securely tighten setscrew to XX
A
B
C D E
A. Terminal lug | D. Neutral (white) wire |
B. Setscrew | E. Line 2 (red) wire |
C. Line 1 (black) wire |
|
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20
Wire Awg | Torque |
8 gauge copper | 25 |
|
|
6 gauge aluminum | 35 |
|
|
5.Use Phillips screwdriver to connect the bare (green) ground wire to the range with the
6.Use ³⁄₈" nut driver to connect the neutral (white) lug to the center terminal block post with one of the
G
A
B
|
| F |
| D | E |
C |
| |
|
| |
A. |
| E. Neutral (white) wire |
B. Line 1 (black) |
| F. Line 2 (red) |
C. Bare (green) ground wire | G. Terminal lug |
D.
7.Connect line 1 (black) and line 2 (red) terminal lugs to the outer terminal block posts with
8.Securely tighten hex nuts.
9.Replace terminal block access cover.
3-wire connection: Direct Wire
Use this method only if local codes permit connecting ground conductor to neutral supply wire.
1.Pull the conduit through the hole and conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.
A
B
|
| C |
|
| D |
F | E |
|
|
| |
A. Terminal block | D. Line 2 | (red) wire |
B. | E. Bare (green) ground wire | |
C. Cord/conduit plate | F. Line 1 | (black) wire |
13