KitchenAid W10526086A For direct-wired ranges, Replace all parts and panels before operating

Models: W10526086A

1 40
Download 40 pages 19.64 Kb
Page 21
Image 21
For direct-wired ranges:

For direct-wired ranges:

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.Turn manual shutoff valve to the closed position.

3.Disconnect wiring.

4.Disconnect the gas supply tubing.

5.Complete cleaning or maintenance.

6.Reconnect the gas supply tubing.

7.Reconnect wiring.

8.Slide range back so rear range foot is under anti-tip bracket.

9.Refer to the “Verify Anti-Tip Bracket Is Installed and Engaged” section to verify engagement.

10.Check that range is level.

11.Open the manual shutoff valve in the gas supply line.

12.Reconnect power.

21

Page 21
Image 21
KitchenAid W10526086A For direct-wired ranges, Electrical Shock Hazard Disconnect power before servicing