Sierra 241-VTP, 240-VTP instruction manual Appendix a Specifications

Models: 241-VTP 240-VT 240-VTP 241-VT

1 92
Download 92 pages 12.04 Kb
Page 68
Image 68

 

Appendix A Specifications

 

 

 

 

 

 

Series 24-HP Instruction Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Air Minimum and Maximum Flow Rates (SCFM)

 

 

 

 

 

 

 

 

Air at 70oF

 

 

 

 

 

 

 

 

 

 

Nominal Pipe Size (in)

 

 

 

 

 

 

Pressure

0.5

0.75

1

 

1.5

2

 

3

 

4

6

8

 

0 psig

1.8

3

5

 

13

22

 

50

 

87

198

347

 

18

41

90

 

221

369

 

826

 

1437

3258

5708

 

 

 

 

 

 

100 psig

5

9

15

 

38

63

 

141

 

245

555

972

 

138

325

704

 

1730

2890

 

6466

 

11254

25515

44698

 

 

 

 

 

 

200 psig

7

13

21

 

52

86

 

193

 

335

761

1332

 

258

609

1322

 

3248

5427

 

12140

 

21131

47911

83931

 

 

 

 

 

 

300 psig

8

15

25

 

63

104

 

234

 

407

922

1615

 

380

896

1944

 

4775

7978

 

17847

 

31064

70431

123375

 

 

 

 

 

 

400 psig

10

18

29

 

72

120

 

269

 

467

1060

1857

 

502

1183

2568

 

6309

10542

 

23580

 

41043

93057

163000

 

 

 

 

 

 

500 psig

11

20

33

 

80

134

 

300

 

521

1182

2071

 

624

1472

3195

 

7849

13115

 

28034

 

51063

115775

203000

 

 

 

 

 

 

 

 

 

Typical Air Minimum and Maximum Flow Rates (nm3/hr)

 

 

 

 

 

 

 

 

Air at 20oC

 

 

 

 

 

 

 

 

 

 

Nominal Pipe Size (mm)

 

 

 

 

Pressure

 

15

 

20

25

40

 

50

80

100

 

150

200

0 barg

 

3

 

5

9

21

 

36

79

138

 

313

549

 

28

 

66

142

350

 

584

1307

2275

 

5157

9034

 

 

 

 

 

5 barg

 

7

 

13

21

52

 

87

194

337

 

764

1339

 

165

 

390

847

2080

 

3476

7775

13533

 

30682

53749

 

 

 

 

 

10 barg

 

9

 

17

29

70

 

117

262

457

 

1035

1814

 

304

 

716

1554

3819

 

6381

14273

24844

 

56329

98676

 

 

 

 

 

15 barg

 

11

 

21

34

85

 

142

317

551

 

1250

2190

 

442

 

1044

2265

5565

 

9299

20801

36205

 

82087

143801

 

 

 

 

 

20 barg

 

13

 

24

40

97

 

162

363

632

 

1434

2511

 

582

 

1373

2979

7318

 

12229

27354

47612

 

107949

189105

 

 

 

 

 

30 barg

 

16

 

29

48

118

 

198

442

770

 

1745

3057

 

862

 

2034

4414

10843

 

18119

40529

70544

 

159942

280187

 

 

 

 

 

Linear Range

 

Smart electronics corrects for lower flow down to a Reynolds number of 5,000. The Reynolds

 

 

 

 

 

 

number is calculated using the fluid’s actual temperature and pres-

 

 

 

 

 

 

sure monitored by the meter. Rangeability depends on the fluid,

 

 

 

 

 

 

process connections and pipe size. Consult factory for your applica-

 

 

 

 

 

 

tion. Velocity rangeability under ideal conditions is as follows:

 

 

 

Liquids 30:1

 

1 foot per second velocity minimum

 

 

 

 

 

 

 

 

 

30 feet per second velocity maximum

 

 

 

 

 

Gases 30:1

 

10 feet per second velocity minimum

 

 

 

 

 

 

 

 

 

300 feet per second velocity maximum

 

A-2

IM-24-HP

Page 68
Image 68
Sierra 241-VTP, 240-VTP instruction manual Appendix a Specifications