Sierra 241-VTP, 240-VTP instruction manual Electronics Assembly Replacement All Meters

Models: 241-VTP 240-VT 240-VTP 241-VT

1 92
Download 92 pages 12.04 Kb
Page 65
Image 65

Series 24-HP Instruction Manual

Chapter 4 Troubleshooting & Repair

 

 

Warning! Before attempting any flow meter re- pair, verify that the line is not pressur-

nector on the temperature / pressure board. The current should be approximately .0004 amps.

3.Go to the first column of the hidden diagnostics and record the Pe(V) and Pv(V) values and consult the factory with findings.

Electronics Assembly Replacement (All Meters)

The electronics boards are electrostatically sensitive. Wear a grounding wrist strap and make sure to observe proper handling precautions required for static-sensitive components.

1.Turn off power to the unit.

2.Locate and loosen the small set screw which locks the larger enclosure cover in place. Unscrew the cover to expose the elec- tronics stack.

3.Locate the sensor harnesses which come up from the neck of the flow meter and attaches to the circuit boards. Use small pli- ers to pull the sensor wiring connectors off of the circuit boards.

4.Locate and loosen the small set screw which locks the smaller enclosure cover in place. Unscrew the cover to expose the field wiring strip. Tag and remove the field wires.

5.Remove the screws that hold the black wiring label in place, remove the label.

6.Locate the 4 Phillips head screws which are spaced at 90- degrees around the terminal board. These screws hold the elec- tronics stack in the enclosure. Loosen these screws (Note: that these are captive screws, they will stay inside the enclosure).

7.Carefully remove the electronics stack from the opposite side of the enclosure. If the electronics stack will not come out, gen- tly tap the terminal strip with the screw driver handle. This will loosen the rubber sealing gasket on the other side of the enclo- sure wall. Be careful that the stack does not hang up on the loose sensor harnesses.

8.Repeat steps 1 through 6 in reverse order to install the new electronics stack.

IM-24-HP

4-9

Page 65
Image 65
Sierra 241-VTP, 240-VTP instruction manual Electronics Assembly Replacement All Meters