Chapter 1 Introduction

Series 24-HP Instruction Manual

 

 

As shown in Figure 1-3, Innova-Mass™ meters exhibit a constant Strou- hal number across a large range of Reynolds numbers, indicating a con- sistent linear output over a wide range of flows and fluid types. Below this linear range, the intelligent electronics in Innova-Mass automatically corrects for the variation in the Strouhal number with the Reynolds num- ber. The meter’s smart electronics corrects for this non-linearity via its simultaneous measurements of the process fluid temperature and pres- sure. This data is then used to calculate the Reynolds number in real time. Innova-Mass meters automatically correct down to a Reynolds number of 5,000.

Strouhal Number, St

Corrected range

0.3

Linear range

0.2

0.1

0.0

103

 

104

10 5

10 6

107

10 8

 

 

 

 

5000

Reynolds Number, Re

 

 

 

 

 

Figure 1-3. Reynolds Number Range for the Innova-Mass

Temperature Measurement

Innova-Mass Flow Meters use a 1000 ohm platinum resistance temperature detector (PRTD) to measure fluid temperature.

1-6

IM-24-HP

Page 12
Image 12
Sierra 241-VTP, 240-VTP instruction manual Temperature Measurement, Reynolds Number Range for the Innova-Mass