Kodak 9500 manual Permanently changing a group of parameters

Models: 9500

1 101
Download 101 pages 52.87 Kb
Page 60
Image 60

Permanently changing a group of parameters

A permanent change to a group of parameters is performed by temporarily overriding a group of parameters and then sending a scanner-unique Define Mode (JA) command to save the values to a specified mode.**

The permanent parameter changes remain in effect until a SCSI or power-on reset occurs.

The following table illustrates how the use of a scanner-unique JA command can be used to permanently change a group of current mode parameters:

 

RESULT

ACTION

Compression

Resolution

Scanner is in Mode 1

3*

200*

Host executes SCSI Send command

2

300

with 2FX300BX

 

 

Host executes SCSI Send command

 

 

with 4JA

 

 

Host executed SCSI Send command

2

300

with 4HA

 

 

Host executes SCSI Send command

3*

200*

with 1HA

 

 

Scanner is in Mode 1

3*

200*

Host executes SCSI Send command

2

300

with 2FX300BX4JA

 

 

Host executed SCSI Send command

2

300

with 4HA

 

 

Host executes SCSI Send command

3*

200*

with 1HA

 

 

*Parameter default value.

**The value(s) may be saved to the current mode or any of the other modes.

A-61124 March 1999

6-17

Page 60
Image 60
Kodak 9500 manual Permanently changing a group of parameters