Kodak 9500 manual Define Window Parameters data, Descriptor Data Definition

Models: 9500

1 101
Download 101 pages 52.87 Kb
Page 26
Image 26

Define Window Parameters data

Descriptor

Data

 

 

Definition

Window Identifier

= SFFFFF00

S=Side (0-Front, 1-Rear)

 

 

FFFFF=Mode (0-18)

Auto

= 0

Auto windows not supported

X Resolution

= 0

If zero, will default to 200 dpi

 

= 70 to 300

Document Scanner 9500

Y Resolution

=

Defaults to X resolution

Upper Left X

= 0 to 14400*

0 to 12 inches (0 to 304.8 mm)

Upper Left Y

= 0 to 24000*

0 to 20 inches (0 to 508 mm)

Width

= 0,96 to 14400*

0 or 0.08 to 12 inches (2 to 304.8 mm)

Length

= 0,96 to 36000*

0 or 0.08 to 30 inches (2 to 762 mm)

Brightness

= 0

Automatic brightness not supported

Threshold

= 0, 1 to 255

When zero and "Allow Zero for Threshold &

 

 

Contrast" is zero, return to default value

Contrast

= 0, 1 to 255

Percentage of adaptive threshold. When zero,

 

 

and "Allow Zero for Threshold & Contrast" is zero,

 

 

return to default value

Image Composition

= 00H, 01H

00H = Bi-level (default)

 

 

01H = Dithered (see halftone pattern)

Bits per Pixel

= 1

Only one bit available (8 bits internal)

Halftone Pattern

= 0 to 7**

ATP On:

 

 

0

= 2-level screen (no screen)

 

 

ATP Off:

 

 

1

= 16-level screen

 

 

2

= 32-level screen

 

 

3

= 64-level screen

 

 

4

= 3-level screen

 

 

5=

4-level Bayer dither

 

 

6=

16-level Bayer dither

 

 

7=

64-level Bayer dither

RIF

= 0, 1

0

= zero white, one black

 

 

1

= zero black, one white (default)

Padding Type

= 00H

Pad with 0s cannot be disabled

 

 

 

 

 

*Measurement unit for scan region parameters is 1/1200 inch (0.0212 mm).

** Image Composition

Halftone Pattern

Result

00

any

Halftone Pattern -> 0

00

0

No dithering (ATP or fixed threshold)

01

any

Dither using specified halftone pattern

01

0

Image Composition -> 0

If the Digital Science Image Manager is installed and enabled and all four parameters are 0, auto- cropping is selected. If the Digital Science Image Manager is not installed and enabled, 0000 should not be used.

5-10

A-61124 March 1999

Page 26
Image 26
Kodak 9500 manual Define Window Parameters data, Descriptor Data Definition