13. ELECTRICAL CONNECTIONS - WALL TIMER VERSIONS

A. IDENTIFY ELECTRICAL REQUIREMENTS

The model number is printed on a plate at the pump end of the module.

The model number identifies electrical rating. Electrical connections for each model vary.

SK-1200-AC, K-1205-AC, K-1210-AC,

K-1215-AC, K-1220-AC:

60 Hz

See Electrical Requirements section on page 11 of Product Requirements.

B.WIRING INFORMATION - 120 V, 60 HZ –

WALL TIMER VERSIONS

DANGER: Risk of electrical shock. Do not mount timer within reach of whirlpool user.

WARNING: Risk of electrical shock. To reduce the risk of electric shock, connect only to a properly grounded, grounding-type receptacle, protected by a Ground-FaultCircuit-Interrupter (GFCI). Do not remove the plug’s grounding pin. Do not use a grounding adapter.

Your Kohler Whirlpool bath is equipped with a cord and plug. All wiring of the pump and control has been completed at the factory. A licensed electrician must install a GFCI protected, 120 Volt, 15 Amp, grounded outlet. Your whirlpool may then be plugged into this outlet. No other load should be on this circuit. Locate the outlet within reach of the 36” cord.

Install wiring from the GFCI to the wall timer location. Use a switch box with adequate capacity.

Black (Line)

TIMER

White (Neutral)

Black

G

Black

F

C

 

I

PUMP

Green (Ground)

 

White White

Green

Green

106548-CA(9437)

20

Kohler Co., Kohler WI

Page 20
Image 20