12. ELECTRICAL CONNECTIONS - AIR ACTUATOR VERSIONS

A. IDENTIFY ELECTRICAL REQUIREMENTS

The model number is printed on a plate at the pump end of the module.

The model number identifies electrical rating. Electrical connections for each model vary.

SK-1201-AC, K-1206-AC, K-1211-AC,

K-1216-AC, K-1221-AC:

60 Hz

(Follow Step B. below.)

 

SK-1201-J1-AA, K-1201-J1-AB, K-1206-J1-AA, K-1206-J1-AB, K-1211-J1-AA, K-1211-J1-AB,

K-1216-J1-AA, K-1221-J1-AA:

60 Hz

(Follow Steps C. and D. below.)

 

SK-1201-JA-AA, K-1206-JA-AA, K-1211-JA-AA,

K-1216-JA-AA, K-1221-JA-AA:

50 Hz

(Follow Steps E. and F. below.)

 

See Electrical Requirements section on page 11 of

Product Requirements.

B. WIRING INFORMATION - 120 V, 60 HZ (EXCLUDING -J1 MODELS)

WARNING: Risk of electrical shock. To reduce the risk of electric shock, connect only to a properly grounded, grounding-type receptacle, protected by a Ground-FaultCircuit-Interrupter (GFCI). Do not remove the plug’s grounding pin. Do not use a grounding adapter.

Your Kohler Whirlpool bath is equipped with a cord and plug. All wiring of the pump and control has been completed at the factory. A licensed electrician must install a GFCI protected, 120 Volt, 15 Amp, grounded outlet. Your whirlpool may then be plugged into this outlet. No other load should be on this circuit. Locate the outlet within reach of the 36” cord.

Kohler Co., Kohler WI

17

106548-CA(9437)

Page 17