1. ROUGHING-IN: K-1200-AC, K-1201-AC

A. ORDERING INFORMATION

Factory installed components include pump and air switch transmitter.

Information contained in this roughing-in also applies to K-1201-J1-AA, K-1201-J1-AB and K-1201-JA-AA.

Whirlpool with wall timer

 

K-1200-AC

 

 

 

Whirlpool with air actuator (shown)

K-1201-AC

 

 

 

Accessories/hardware:

 

 

 

 

 

Drain

K-7161-AF

recom-

 

 

mended

 

 

 

Vinyl tiling-in bead*

K-1177

optional

 

 

 

*Use K-1177 vinyl bead when wall material contacts any top surface of bath.

B. REQUIRED ELECTRICAL SERVICE

Dedicated circuits required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):

Pump/control

120 V., 15 A, 60 Hz

 

 

C. PRODUCT INFORMATION

Fixture:

basin area

top area

 

weight

 

 

 

 

 

 

 

Bathing well

42” x 17”

55” x 25”

 

93 lbs.

 

 

 

 

 

 

 

 

water depth

capacity

 

 

 

 

 

 

 

 

 

 

To overflow

12-1/8”

50 gals.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump:

 

hp

V

Hz

 

A

 

 

 

 

 

 

 

60 Hz

 

1/2

120

60

 

8

 

 

 

 

 

 

 

D. INSTALLATION NOTES

Refer to installation instructions included with fixture before beginning installation.

ROUGHING-IN NOTES

Fixture dimensions are nominal and conform to toler- ances in ANSI Standard Z124.1.

No change in measurements if connected with drain illustrated.

 

Cut-out

28-1/2” x 58-1/2”

 

Minimum access:

 

FIELD WIRING COMPARTMENT

Pump/control box

20” W x 15” H panel required

15”

PUMP

 

 

 

1-1/2”

 

PUMP/CONTROL ACCESS

 

 

 

8-1/2”

30”

 

60”

2-3/4”

1-1/2”

 

 

 

17”

 

2-7/8”

3/16”

 

3”

1-1/2” I.P.S. THR’D

1.25>132

 

1-1/2” O.D.

Kohler Co., Kohler WI