5. ROUGHING-IN: K-1220-AC, K-1221-AC

A. ORDERING INFORMATION

Factory installed components include pump and air switch transmitter.

Information contained in this roughing-in also applies to K-1221-J1-AA and K-1221-JA-AA.

Whirlpool with wall timer

 

K-1220-AC

 

 

 

Whirlpool with air switch (shown)

K-1221-AC

 

 

 

Accessories/hardware:

 

 

 

 

 

Drain

K-7161-AF

recom-

 

 

mended

 

 

 

Apron

K-1223

optional

 

 

 

Vinyl tiling-in bead*

K-1179

optional

 

 

 

*Use K-1179 vinyl bead when wall material contacts any top surface of bath.

B. REQUIRED ELECTRICAL SERVICE

Dedicated circuits required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):

Pump/control

120 V., 15 A, 60 Hz

 

 

C. PRODUCT INFORMATION

Fixture:

basin area

top area

 

 

weight

 

 

 

 

 

 

 

 

 

 

 

Bathing well

47” x 37”

67” x 32”

 

 

120 lbs.

 

 

 

 

 

 

 

 

 

 

 

 

water depth

capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To overflow

16-7/8”

117 gals.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump, 1 phase

hp

RPM

V

 

Hz

 

A

 

 

 

 

 

 

 

 

 

60 Hz

 

3/4

3450

120

 

60

 

10

 

 

 

 

 

 

 

 

 

 

D. INSTALLATION NOTES

Refer to installation instructions included with fixture before beginning installation.

*Some K-1179 tiling-in beads may require trimming of the bottom edge for proper fit.

24”

FIELD WIRING

COMPARTMENT

PUMP

2”

9”

72”

3-1/2”

2-7/8” 13/16”

3”

Kohler Co., Kohler WI

ROUGHING-IN NOTES

Fixture dimensions are nominal and conform to toler- ances in ANSI Standard Z124.1.

No change in measurements if connected with drain illustrated.

Cut-out

46-1/4” x 70-1/4”

 

 

 

Minimum access:

 

 

 

 

 

Pump/control box

20” W x 15” H panel

required

 

 

 

PUMP/CONTROL ACCESS

48”

1-3/4”

23”

1-1/2” I.P.S. THR’D

 

1-1/2” O.D.

1.15>132

 

 

9

 

106548-CA(9437)

Page 9
Image 9