4. ROUGHING-IN: K-1215-AC, K-1216-AC

A. ORDERING INFORMATION

Factory installed components include pump and air switch transmitter.

Information contained in this roughing-in also applies to K-1216-J1-AA and K-1216-JA-AA.

Whirlpool with wall timer

 

K-1215-AC

 

 

 

Whirlpool with air actuator (shown)

K-1216-AC

 

 

 

Accessories/hardware:

 

 

 

 

 

Drain

K-7161-AF

recom-

 

 

mended

 

 

 

Vinyl tiling-in bead*

K-1179

optional

 

 

 

*Use K-1179 vinyl bead when wall material contacts any top surface of bath.

B. REQUIRED ELECTRICAL SERVICE

Dedicated circuits required, protected with Class A Ground-Fault Circuit-Interrupter (GFCI):

Pump/control

120 V., 15 A, 60 Hz

 

 

C. PRODUCT INFORMATION

Fixture:

basin area

top area

 

weight

 

 

 

 

 

 

 

Bathing well

52” x 23”

65-1/2” x

 

95 lbs.

 

 

 

26-1/2”

 

 

 

 

 

 

 

 

 

 

 

water depth

capacity

 

 

 

 

 

 

 

 

 

 

To overflow

15-1/2”

76 gals.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump:

 

hp

V

Hz

 

A

 

 

 

 

 

 

 

60 Hz

 

3/4

120

60

 

10

 

 

 

 

 

 

 

D. INSTALLATION NOTES

Refer to installation instructions included with fixture before beginning installation.

*Some K-1179 tiling-in beads may require trimming of the bottom edge for proper fit.

18”

1-7/8”

3”

FIELD WIRING COMPARTMENT

PUMP

8-7/8”

71-3/16”

ROUGHING-IN NOTES

Fixture dimensions are nominal and conform to toler- ances in ANSI Standard Z124.1.

No change in measurements if connected with drain illustrated.

Cut-out

34-1/2” x 70”

 

 

 

Minimum access:

 

 

 

 

 

Pump/control box

20” W x 15” H panel

required

 

 

 

PUMP/CONTROL ACCESS 36”

1-3/4”

21”

2-7/8”

3”

1.25>132

15/16”

1-1/2” I.P.S. THR’D

1-1/2” O.D.

106548-CA(9437)

8

Kohler Co., Kohler WI

Page 8
Image 8