Kramer Electronics VS-88DTP user manual Storing and Recalling Setups in Presets, To store a setup

Models: VS-88DTP

1 55
Download 55 pages 42.16 Kb
Page 23
Image 23
6.3Storing and Recalling Setups in Presets

6.3Storing and Recalling Setups in Presets

You can use the STO and RCL buttons to store and recall up to 16 setups in presets. Figure 9 illustrates the preset assignment numbers. Preset 1 is assigned to OUT 1 and preset 16 is assigned to IN 8.

Note: The preset numbers do not appear on the buttons.

Figure 9: Preset Number Assignments using the Selector Buttons

To store a setup:

1.Route inputs and outputs as required.

2.Press the STO button. The STO button flashes.

3.Select a preset number in which to store the current configuration (for example, for preset 13, press IN 5).

To recall a setup:

1.Press the RCL button. The RCL button flashes.

2.Press the required preset button (for example, for preset 13, press IN 5).

6.4Switching Between Protocol 2000 and Protocol 3000

To switch to Protocol 2000:

Press the Output 1 and Output 2 buttons at the same time.

The device switches to Protocol 2000 and the display shows 2000

To switch to Protocol 3000:

Press the Output 1 and Output 3 buttons at the same time.

The device switches to Protocol 3000 and the display shows 3000

VS-88DTP - Operating the VS-88DTP

19

Page 23
Image 23
Kramer Electronics VS-88DTP Storing and Recalling Setups in Presets, Switching Between Protocol 2000 and Protocol