KTI Networks KC-1300 operation manual Factory default settings of the Console port

Models: KC-1300

1 63
Download 63 pages 23.19 Kb
Page 26
Image 26

2.Connect one end to the console port and connect the other end to the PC COM port.

3.Configure your PC COM port setting to match the RS-232 settings of the console port and start your terminal software.

Factory default settings of the Console port

Baud rate : 38400, N, 8, 1, 0

Flow control : disabled

4.Turn the system power on.

5.Press <Enter> key several times in your terminal software until a login prompt comes up. It means the connection is proper.

The console port does not support modem connection.

Refer to Chapter 4 for more information about Console management.

-26-