-44-
5.3 SNMP Traps
The system also supports the following SNMP traps. When the trap
event occurs, the SNMP agent will generate a trap notification to SNMP
management station.
Trap Name Event of Trap Generated
Cold Start The system is powered on and complete
initialization
Authentication failure SNMP community authentication failure
Power status Any power failure of Power1and Power2
Power status Any power recovery of Power1 and Power2
Fan status Fan failure
Fan status Fan recovery
Slot # Port A link Slot # MC Port A link down or up
Slot # Port A link Slot # MC Port A link recovery
Slot # Port B link Slot # MC Port B link down or up
Slot # Port B link Slot # MC Port B link recovery
Slot # RTP link Slot # remote MC TP link change
The binding information together with a trap is :
Trap Name VarBind
Cold Start sysDescr, ie KC-1300
Authentication failure sysDescr, ie, KC-1300
Power Status Power status for Power1 and Power2
Fan Status Fan status
Slot # Port A link Slot description and Port A link status
Slot # Port B link Slot description and Port B link status
Slot # RTP link Slot description and remote MC TP link status
Remark:
1. The slot # can be slot 1 up to slot 16.
2. Port A : the upper port of the MC installed in slot.
3. Port B : the lower port of the MC installed in slot.