ADJUSTMENTS

ADJUSTMENTS

Always disconnect the appliance from the electricitymainbeforemakinganyadjustments. All seals must be replaced by the technician at theendofanyadjustmentsorregulations.

Our burners do not require primary air adjustment.

11) TAPS

“Reducedrate”adjustment

Switch on the burner and turn the relative knob to the“Reducedrate”position(smallflamefig.1). Remove knob “M” (fig. 13) of the tap, which is simplypressedontoitsrod.

Insert a small screwdriver “D” into hole “C” (fig. 13) and turn the throttle screw to the right or left until the burner flame has been adequately regulated to the“Reducedrate”position.

Check that the flame does not go out when the knob is sharply switched from the “Full on” to the “Reduced rate” position.

It is understood that only burners operating with Natural Gas or Town gas should be subjected to the above mentioned adjustments. The screw must be fully locked when the burners operate with Propane HD-5 (turn clockwise).

In the case of a “DUAL” burner, the regulation screw situated inside the post of the valve regulates the central flame, while the screw next to the valve regulates the outer flame.

The operations described above can be carried out easily, whatever the position of the hob or however it is fastened to the unit.

THE BURNERS DO NOT REQUIRE ANY REGULATIONOFTHEPRIMARYAIR.

FIG. 13

14