STEP 2:

65

ELEVATION POTENTIOMETER CALIBRATION

ELEVATION

 

POTENTIOMETER

ELEVATION MOTOR

P/N #71013

P/N #70088 110volt

 

P/N #70126 220volt

ADJUSTMENT

 

SHAFT

 

ELEVATION NUT

NOTE: ELONGATED BRACKET HOLES ARE FOR

POTENTIOMETER FINE ADJUSTMENT.

Enter Diagnostic Mode:

2.Power up treadmill in Diagnostic Mode:

Sprint – Press DISPLAY & START simultaneously.

SST & PRG – Press MANUAL & START simultaneously.

Calibrate the elevation potentiometer:

1.Visually confirm treadmill is level. (0% grade)

2.The potentiometer should read between –0.6and -0in.1the selectable display window.

3.If the setting is incorrect, follow the steps below.

STEP 1: Turn the post of the potentiometer all the way

CLOCKWISE.

Slowly turn the potentiometer COUNTER-CLOCKWISEuntil the setting is correct.

4.Carefully install potentiometer into the motor housing.

*NOTE: The setting may vary when inserting the potentiometer into the motor. As long as the change is minimal, fine adjustment can be achieved after the potentiometer is secured in motor housing.

5.Press OFF to turn treadmill off.