65
ELEVATION POTENTIOMETER CALIBRATION
ELEVATION |
| |
POTENTIOMETER | ELEVATION MOTOR | |
P/N #71013 | ||
P/N #70088 110volt | ||
| P/N #70126 220volt | |
ADJUSTMENT |
| |
SHAFT |
|
ELEVATION NUT
NOTE: ELONGATED BRACKET HOLES ARE FOR
POTENTIOMETER FINE ADJUSTMENT.
Enter Diagnostic Mode:
2.Power up treadmill in Diagnostic Mode:
Sprint – Press DISPLAY & START simultaneously.
SST & PRG – Press MANUAL & START simultaneously.
Calibrate the elevation potentiometer:
1.Visually confirm treadmill is level. (0% grade)
2.The potentiometer should read between
3.If the setting is incorrect, follow the steps below.
STEP 1: Turn the post of the potentiometer all the way
CLOCKWISE.
Slowly turn the potentiometer
4.Carefully install potentiometer into the motor housing.
*NOTE: The setting may vary when inserting the potentiometer into the motor. As long as the change is minimal, fine adjustment can be achieved after the potentiometer is secured in motor housing.
5.Press OFF to turn treadmill off.