68
Reed Switch
A read switch mounted on the display board shall be used to detect the presence of a magnet attached to a safety lanyard. In the event the magnet is removed. The
Mechanical Buttons.
(6)Mechanical buttons identical to the one on the sample display board shall be used to input
ON/OFF INCREASE SPEED DECREASE SPEED ELEVATION UP ELEVATION DOWN SCAN DISPLAY
On Board Displays
(2) 7 segment speed display (same as on existing board)
(4)7 segment multiplex display (Time, Distance, Elevation, Calories)
(4)Green LEDs to indicate which mode the multiplexed display is in.
Display Board Inputs: |
|
+9VDC unregulated | (600mA total power for entire system including relays) |
Ground
Elevation Grade Pot Sense - Analog input
Speed Sense - Digital Input
Display Board Outputs
+6VDC Relay Power - Powers (3)
shorts.
| Connected to coil of |
Connected to coil of | |
Connected to coil of | |
Speed Control | (digital pulse train - current loop) |