Diagnostic Codes
If the stove operates abnormally, the ready light on the control board will signal the nature of the abnormal operation. The following is a list of possible signals or codes:
Ready light is constant red | Ignition Failure |
Ready light flashes red 1 short and 1 long blink | Vacuum Switch Open |
Ready light flashes red 2 short blinks | Proof of Fire Snap Switch Open |
Ready light flashes red 2 long blinks | Over Temperature Snap Switch Open |
Troubleshooting
Ignition Failure - Code - Ready light is constant red and ignite light flashes two short blinks
Possible Problem | Solution |
Hopper is out of pellets | Fill the hopper with pellets |
|
|
Auger tube was not full of pellets when start button was pushed | When cool, empty pellets in burn pot and push start button again |
Burn pot dirty - holes plugged | Clean the burn pot |
Igniter not functioning | Replace the igniter |
|
|
Igniter fuse blown | Replace 6 amp fuse located on front of the control board |
|
|
|
|
Control Board has no Power - When selector knob is turned no lights light up | |
Possible Problem | Solution |
|
|
Power cord is not plugged in | Plug in power cord |
Board fuse blown | Replace 3 amp fuse located on front of control board |
Wall outlet not energized | Check circuit breaker panel |
|
|
Board broken, damaged, or defective | Replace the control board |
|
|
Vacuum Switch Shuts Stove Down - Code - Ready light flashes red 1 short and 1 long blink | |
Possible Problem | Solution |
Front door is not sealing | Latch or adjust the front door or replace door gasket |
|
|
Ash drawer is not sealing | Close latches, adjust latches, or replace drawer gaskets |
Flue gas passageways restricted | Clean the passageways (see page 20) |
Vent pipe restricted | Clean the vent pipe (see page 21) |
|
|
Vacuum hose plugged | Clean or replace the vacuum hose |
Vacuum switch defective | Replace the vacuum switch |
| |
Proof of Fire Snap Switch Shuts Stove Down - Code - Ready light flashes red 2 short blinks | |
Possible Problem | Solution |
|
|
Hopper is out of pellets | Fill the hopper with pellets |
|
|
Auger tube was not full of pellets when start button was pushed | When cool, empty pellets in burn pot and push start button again |
Snap switch* defective | Replace the snap switch |
|
|
Over Temperature Snap Switch Shuts Stove Down - Code - Ready light flashes red 2 long blinks | |
Possible Problem | Solution |
Convection blower not running | Blower dirty, blower snap switch bad, or blower broken |
Flue passageways or vent restricted | Clean passageways or vent pipe (see pages 20 & 21) |
Snap switch* defective | Replace the snap switch* |
|
|
* Note: The snap switch has a reset button that must be pushed before stove will function (see page 23).
25