12" (305mm) MAX. for 2" (51mm)

UNCONDITIONED

20" (508mm) MAX. for 3" (76mm)

 

SPACE

 

6" (152mm)

 

Max

SIZE TER-

 

MINATION

*WALL SUPPORT

PIPE PER

OUTSIDE WALL

TABLE 8.

 

FIELD−PROVIDED

12" (305mm)

REDUCER MAY BE

ABOVE GRADE OR

REQUIRED TO

AVERAGE SNOW

ADAPT LARGER

ACCUMULATION

VENT PIPE SIZE TO

 

TERMINATION

 

1/2" (13mm) FOAM

 

INSULATION IN

 

UNCONDITIONED

1/2" (13mm) FOAM

SPACE

INSULATION

*Use wall support every 24" (610). Use

 

two supports if extension is greater

 

than 24" but less than 48".

 

NON−DIRECT VENT FIELD SUPPLIED WALL TERMINATION EX- TENDED OR (15F74) WALL TERMINATION VENT PIPE EXTENDED

FIGURE 40

ML193DF NON−DIRECT VENT APPLICATION

USING EXISTING CHIMNEY

 

SIZE TERMINATION

 

 

 

STRAIGHT−CUT OR

 

PIPE PER TABLE 8.

 

 

ANGLE−CUT IN DIRECTION

 

 

 

 

OF ROOF SLOPE

 

 

 

 

 

 

3" − 8"

 

 

 

 

 

 

 

EXHAUST VENT

 

 

 

 

 

 

 

 

(76mm−

 

 

1/2" (13mm)

 

 

 

 

 

 

 

 

203mm)

 

 

 

 

 

 

 

 

 

 

 

 

WEATHERPROOF

 

 

Minimum 12" (305MM)

 

 

 

 

 

 

INSULATION

 

 

above chimney top

 

 

 

 

 

 

 

 

 

 

plate or average snow

 

 

 

 

 

 

SHOULDER OF FITTINGS

 

 

accumulation

 

 

 

PROVIDE SUPPORT

 

 

 

 

 

 

 

 

 

OF PIPE ON TOP PLATE

 

 

 

 

 

SHEET

 

 

 

 

 

 

 

 

 

 

METAL TOP

 

 

 

 

 

 

 

 

 

 

PLATE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3" − 8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(76mm−

 

 

 

 

 

 

 

 

203mm)

 

 

INSULATE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO FORM

 

 

 

 

 

 

EXTERIOR

 

 

 

SEAL

 

 

 

 

 

 

PORTION OF

 

 

 

 

 

 

 

 

 

 

 

CHIMNEY

 

NOTE − Do not discharge exhaust gases directly into any chimney or vent stack. If ver- tical discharge through an existing unused chimney or stack is required, insert piping inside chimney until the pipe open end is above top of chimney and terminate as illus- trated. In any exterior portion of chimney, the exhaust vent must be insulated.

FIGURE 41

Condensate Piping

This unit is designed for either right- or left-side exit of con- densate piping. Refer to figure 42 for condensate trap loca- tions.

NOTE − If necessary the condensate trap may be installed up to 5´ away from the furnace. Use PVC pipe to connect trap to furnace condensate outlet. Piping from furnace must slope down a minimum of 1/4" per ft. toward trap.

CONDENSATE TRAP AND PLUG LOCATIONS

Trap

 

(same on

 

right side)

 

1−1/2 in.

Plug

(same on left

 

 

side)

FIGURE 42

1 − Determine which side condensate piping will exit the unit, location of trap, field−provided fittings and length of PVC pipe required to reach available drain.

2 − Remove plug (figure 42) from the cold end header box at the appropriate location on the side of the unit. Install field−provided 1/2" NPT male fitting into cold end head- er box. Use teflon tape or appropriate pipe dope.

3 − Install the cap over the clean out opening at the base of the trap. See figure 45.

NOTE − Vinyl tubing may be used for condensate drain. Tubing must be 1−1/4" OD X 1" ID and should be attached to the drain on the trap using a hose clamp.

4 − Install drain trap using appropriate PVC fittings, glue all joints. Glue the provided drain trap as shown in fig- ure 45. Route the condensate line to an open drain.

NOTE − If necessary the condensate trap may be installed up to 5 feet away from the furnace. Piping from furnace must slope down a minimum of 1/4" per ft. toward trap.

Page 27

Page 27
Image 27
Lennox International Inc MERIT SERIES GAS FURNACE DOWNFLOW AIR DISCHARGE, ML193DF installation instructions