TABLE 2

COMBUSTIBLE FLOORING BASE OPENING SIZE

Cabinet

Catalog

Front to Rear

Side to Side

 

 

 

 

Width

Number

in.

mm

in.

mm

 

 

 

 

 

 

 

 

B Cabinet

11M60

22

559

18 − 3/4

476

(17.5")

 

 

 

 

 

 

 

 

 

 

 

C Cabinet

11M61

22

559

22 − 3/4

578

(21")

 

 

 

 

 

 

 

 

 

 

 

FURNACE

 

COOLING COIL

PROPERLY

 

SIZED FLOOR

 

OPENING

PLENUM

FURNACE

PROPERLY SIZED FLOOR OPENING

SUPPLY AIR

PLENUM

COMBUSTIBLE FLOORING BASE

FIGURE 14

Return Air Opening −− Downflow Units

Return air may be brought in only through the top opening of a furnace installed in the downflow position. The follow- ing steps should be taken when installing plenum:

1 − Bottom edge of plenum should be flanged with a hemmed edge (See figure 15 or 16).

FIGURE 13

2 − After opening is cut, set the combustible flooring base into opening.

3 − Check fiberglass strips on the combustible flooring base to make sure they are properly glued and posi- tioned.

4 − Lower supply air plenum into the combustible flooring base until plenum flanges seal against fiberglass strips.

NOTE − Be careful not to damage fiberglass strips. Check for a tight seal.

5 − Set the furnace over the plenum.

6 − Ensure that the seal between the furnace and plenum is adequate.

Installation on Cooling Coil Cabinet Figure 14

2 − Sealing strips should be used to ensure an airtight seal between the cabinet and the plenum.

3 − In all cases, plenum should be secured to top of fur- nace using sheet metal screws.

4 − Make certain that an adequate seal is made.

PLENUM

(Field Provided) SECURE FROM OUTSIDE CABINET

SEALING STRIP

CABINET

SIDE PANEL

(Field Provided)

 

Side View

FIGURE 15

NOTE − Downflow combustible flooring kit is not used..

1 − Refer to reverse−flow coil installation instructions for correctly sized opening in floor and installation of cabi- net.

2 − When cooling cabinet is in place, set and secure the furnace according to the instructions that are provided with the cooling coil. Secure the furnace to the cabinet.

PLENUM

(Field Provided)

SECURE FROM

 

INSIDE CABINET

Side View

SEALING STRIP (Field Provided)

CABINET

SIDE PANEL

3 − Seal the cabinet and check for air leaks.

FIGURE 16

Page 11

Page 11
Image 11